𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Errors in quantitative dynamic three-dimensional keyhole MR imaging of the breast

✍ Scribed by Donald B. Plewes; Jonathan Bishop; Ian Soutar; Eve Cohen


Publisher
John Wiley and Sons
Year
1995
Tongue
English
Weight
512 KB
Volume
5
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Three-dimensional (3D) keyhole magnetic resonance (MR) imaging has been proposed as a means of providing dynamic monitoring of contrast agent uptake by breast lesions. with complete breast coverage and high spatial and temporal resolution. The 3D keyhole technique dynamically samples the central regions of k-space in both phase-encoding directions and provides high-frequency data from a precontrast acquisition. Errors due to data truncation with two-dimensional and 3D region-of-interest measurements are estimated from a numerical simulation of various implementations of the 3D keyhole technique. Errors were found to increase with increasing temporal resolution and re- duced object she. Errors of 75% are possible for objects with a diameter approaching 1 pixel when a 3D keyhole implementation that samples 50% of phase-encoding data in each direction is used. Preliminary clinical images with this approach illustrate artifacts consistent with inadequate k-space sampling.


πŸ“œ SIMILAR VOLUMES


Two different types of ring-like enhance
✍ Miki Kobayashi; Hiroko Kawashima; Osamu Matsui; Yoh Zen; Masayuki Suzuki; Masafu πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 725 KB

## Abstract ## Purpose To describe two different types of β€œring‐like enhancement” seen on dynamic magnetic resonance imaging (MRI) of breast cancer, and compare their histopathological features. ## Materials and Methods A total of 326 breast carcinomas in 311 patients were evaluated regarding th

Improvement in the reproducibility of re
✍ Hee Chun; Bradley Clymer; Steffen Sammet; Regina M. Koch; Robert Stevens; Michae πŸ“‚ Article πŸ“… 2007 πŸ› John Wiley and Sons 🌐 English βš– 605 KB

## Abstract ## Purpose To augment traditional visual data perception of complex multiparametric imaging data sets by adding auditory feedback to improve the delineation of regions of interest (ROIs) in tumor assessment in dynamic contrast‐enhanced (DCE) MRI. ## Materials and Methods In addition

Assessment of tumor blood flow in breast
✍ Smitha Makkat; Robert Luypaert; Steven Sourbron; Tadeusz Stadnik; Johan De Mey πŸ“‚ Article πŸ“… 2010 πŸ› John Wiley and Sons 🌐 English βš– 275 KB πŸ‘ 1 views

## Abstract ## Purpose: To prospectively evaluate whether dose reduction and the application of a prebolus technique can effectively alleviate signal saturation effects in T1 dynamic contrast enhanced (T1‐DCE) magnetic resonance imaging (MRI) data in breast tumors and lead to increased diagnostic