Ergonomic evaluation of a redesigned surgical instrument

✍ Scribed by M. Miller; J. Ransohoff; E.R. Tichauer


Publisher
Elsevier Science
Year
1971
Tongue
English
Weight
760 KB
Volume
2
Category
Article
ISSN
0003-6870

No coin nor oath required. For personal study only.

✦ Synopsis


Some problems have been encountered with the current design of the bayonet forceps, one of the more frequently used instruments of the neurosurgeon. By studying its function and operational use, a new design was conceived to make the instrument more amenable to the surgeon's hand, ie ergonomically suitable. This was tested in the laboratory and the operating room, and was found superior to the old one in comfort, stability-in-use, and ease of operation. This method of ergonomic redesign and evaluation can be used for other similar problems.


πŸ“œ SIMILAR VOLUMES


Metallic surgical instruments for interv
✍ Frank G. Shellock πŸ“‚ Article πŸ“… 2001 πŸ› John Wiley and Sons 🌐 English βš– 131 KB πŸ‘ 1 views

This investigation evaluated metallic surgical instruments for magnetic resonance (MR) safety in association with a 1.5-Tesla/64-MHz MR system. Seven different instruments (mallet, bone punch, curette, Weil-Blakesley ethmoid forceps, suction cannula, septum speculum, and Kocher-Langenbeck retractor;

Evaluation of a workplace redesign of a
✍ Anja Johansson; Gerd Johansson; Peter Lundqvist; Ingrid Γ…kesson; Per Odenrick; R πŸ“‚ Article πŸ“… 1998 πŸ› Elsevier Science 🌐 English βš– 132 KB

The aim of this study was to evaluate the effects on the working postures and movements of a cashier when two different locations of the scales (one to the left of the cashier, the other under the conveyer belt in front of the cashier) were used in a grocery checkout system. Two cashiers (of average

Evaluation of a screening instrument for
✍ Delia Lorenz; Frank Papengut; Henrik Frederiksen; Florian Kopper; Stephan Klebe; πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 119 KB

## Abstract To evaluate a screening instrument for essential tremor (ET) consisting of a seven‐item questionnaire and a spiral drawing. A total of 2,448 Danish twins aged 70 years or more and a second sample aged 60 years or more (n = 1,684) from a population‐based northern German cross‐sectional s

Ceramic surgical instruments: Ex vivo ev
✍ Frank G. Shellock; Vincent J. Shellock πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 362 KB

## Abstract The purpose of this study was to evaluate the MR compatibility of ceramic instruments. Nine different ceramic instruments were tested with respect to ferromagnetism, heating, and artifacts using previously described techniques. There was no magnetic field attraction, temperature increas