𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Enzymatic determination of bilirubin fractions in serum

✍ Scribed by Akira Kosaka; Chieko Yamamoto; Yoshitaka Morishita; Kiyoshi Nakane


Book ID
103039138
Publisher
Elsevier Science
Year
1987
Tongue
English
Weight
920 KB
Volume
20
Category
Article
ISSN
0009-9120

No coin nor oath required. For personal study only.

✦ Synopsis


Novel enzymatic methods using bilirubin oxidase from Myrothecium verrucaria are described for the determination of bilirubin fractions in serum. These fractions include an unconjugated form (Bu), a conjugated form (Bc), and a delta fraction of bilirubin that reacts with direct diazo reagent and is irreversibly bound to serum albumin (B8). The determination is based on the different reactivities of the enzyme to bilirubin fractions at different pH in the presence or absence of anionic detergent such as sodium dodecyl sulfate (SDS) or sodium cholate. Thus, in the absence of detergents, Bc and B8 are oxidized at acidic pH, while Sc is oxidized at alkaline pH; Bu is not oxidized at either acidic or alkaline pH.

The first approach is based on measuring the decreased absorbance of bilirubin colour at 450 nm caused by the enzymatic oxidation. Total bflirubin is measured at pH 3.0 in the presence of SDS. Direct bilirubin is measured at pH 3.7 and Bc is measured at pH 10.0 in the absence of SDS, respectively.

The second approach is made by coupling the diazo reaction with the enzyme reaction. Total and direct bilirubin are determined by a conventional diazo method without prior treatment by the enzyme. BS is determined with a direct diazo method after the serum sample is treated at pH 10.0 by the enzyme to oxidize the Bc fraction. The precision and the accuracy of these methods were compared with a diazo method, an HPLC method and a slide method, and good results were obtained.


πŸ“œ SIMILAR VOLUMES


Enzymatic assay for conjugated bilirubin
✍ Shigeki Kimura; Shigeru Iyama; Yoshihisa Yamaguchi; Sadao Hayashi; Takehiko Yana πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 112 KB

We described an automated enzymatic assay for conjugated bilirubin (Bc) in serum using the Iatro D-Bil kit, with bilirubin oxidase (EC 1.3.3.5 BOD) from Myrothecium species. The specificity of the enzyme in the Iatro D-Bil kit was examined by analyzing unconjugated bilirubin (Bu), delta bilirubin (B

Flow-injection spectrophotometric enzyma
✍ J.M. FernΓ‘ndez-Romero; M.D. Luque de Castro; M. ValcΓ‘rcel πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 694 KB

Two automatic spectrophotometric methods based on the use of flow-injection analysis are proposed for the determination of total and direct (conjugated) bilirubin in serum. The first method is based on the oxidation of bilirubin catalysed by bilirubin oxidase and it uses an adaptation of reagent inj