𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Enhancement of the kinetics of the aeration of ethylene oxide sterilized polymers using microwave radiation

✍ Scribed by Matthews, I. P. ;Gibson, C. ;Samuel, A. H.


Publisher
John Wiley and Sons
Year
1989
Tongue
English
Weight
744 KB
Volume
23
Category
Article
ISSN
0021-9304

No coin nor oath required. For personal study only.

✦ Synopsis


Ethylene oxide (EO) is used extensively to sterilize medical supplies that are heat sensitive. EO residues in materials post sterilization can present a hazard to patients at the point of use. Protracted aeration (i.e. degassing) times are necessary post sterilization to reduce EO residues to an accepted level. The sorption of EO into polyvinylchloride was found to be an active process given that at sorption equilibrium (i.e. when the net flow of diffusant into the host material has reduced to zero) the number of molecules of EO per unit volume was greater in PVC than in its external environment. The diffusion coefficient (D) was concentration (c) dependent and the relationship which best describes this dependence was D(?) In c. The diffusion of EO was dramatically accelerated (as evidenced by a time saving in degassing of up to 400%) if microwave heating (2.45 GHz) was used instead of conventional heating for the same macroscopic temperature. The values of activation energy for diffusion were obtained from the respective Arrhenius plots of diffusion coefficient versus inverse temperature for each process. In general, even small reductions in activation energy can greatly increase the specific rate of reaction. The relative efficacy of microwaves in eliminating EO residues as evidenced by this data occurs as a result of microwaves reducing the activation energy for diffusion by almost a factor of two. The relative efficiency of microwave desorption compared to conventional aeration offers considerable gains in the cost-effectiveness of gas sterilization since it will permit a much greater throughput of material, thereby obviating the need for excessively large inventories of equipment.


📜 SIMILAR VOLUMES


Sterilization of medical devices by ethy
✍ Fábio N. Dias; Marina Ishii; Sergio L. Nogaroto; Bruno Piccini; Thereza C. V. Pe 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 127 KB

## Abstract Ethylene oxide (EO) is used to sterilize Oxygenator and Tubing applied to heart surgery. Residual levels of EO and its derivatives, ethylene chlorohydrin (ECH) and ethylene glycol (EG), may be hazardous to the patients. Therefore, it must be removed by the aeration process. This study a

The Absence of Conventional Polymer–Surf
✍ Cláudio F. Lima; Faruk Nome; Dino Zanette 📂 Article 📅 1997 🏛 Elsevier Science 🌐 English ⚖ 113 KB

Mixtures of sodium monodecyl phosphate (NaDeP) and poly(ethylene oxide) (PEO) have been investigated conductimetrically in 0.05 M succinate buffer, pH 5.20. The conductivity vs NaDeP concentration profiles do not show the classical behavior of PEO-sodium dodecyl sulfate (SDS) mixtures. In the presen

Anionic Polymerization of Ethylene Oxide
✍ Holger Schmalz; Michael G. Lanzendörfer; Volker Abetz; Axel H. E. Müller 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 275 KB

## Abstract Fourier‐transform near‐infrared (FT‐NIR) fiber‐optic spectroscopy was successfully used to monitor the anionic polymerization of ethylene oxide (EO). Kinetic data are provided for the polymerization of EO with the __sec__‐BuLi/Bu^__t__^P~4~ initiating system under different reaction con