An investigation of the embrittlement in
✍
Zheng-Fei Hu; Zhen-Guo Yang
📂
Article
📅
2004
🏛
Elsevier Science
🌐
English
⚖ 368 KB
X20CrMoV12.1 alloy steel used as main steam pipes in power plants exhibits embrittlement at room temperature after long-term service exposure at 550 • C and the embrittlement can be partly removed by retempering. Microstructural observation shows that the carbides in the exposed pipe coarsened heavi