๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Elimination of magnetic field foldover artifacts in MR images

โœ Scribed by David J. Larkman; Amy H. Herlihy; Glyn A. Coutts; Joseph V. Hajnal


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
104 KB
Volume
12
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Elimination of oblique flow artifacts in
โœ Lawrence R. Frank; Adrian P. Crawley; Richard B. Buxton ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 641 KB

## Abstract We present an analysis of how flow oblique to the frequencyโ€encoding direction generates displacement artifacts in MR imaging and show that for flow which has constant velocity between the start of the phase encoding and the center of the echo it is possible to eliminate these artifacts

Correction of concomitant magnetic field
โœ Yiping P. Du; Xiaohong Joe Zhou; Matt A. Bernstein ๐Ÿ“‚ Article ๐Ÿ“… 2002 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 183 KB

Echo-planar images acquired in nonaxial planes are often distorted. Such image distortion has limited the applications of the echo-planar imaging (EPI) technique. In this article, it is demonstrated that a considerable amount of the distortion is caused by the higher-order magnetic field concomitant

Concomitant magnetic-field-induced artif
โœ Xiaohong Joe Zhou; Yiping P. Du; Matt A. Bernstein; H. Glenn Reynolds; Joseph K. ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 947 KB

When a linear magnetic field gradient is used, spatially higher-order magnetic fields are produced to satisfy the Maxwell equations. It has been observed that the higher-order magnetic field produced by the readout gradient causes axial echo planar images acquired with a horizontal solenoid magnet t

Artifacts induced by concomitant magneti
โœ Xiaohong Joe Zhou; Steve G. Tan; Matt A. Bernstein ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 992 KB

## Abstract It has been observed that fast spinโ€echo (FSE) images with a large field of view (>40 cm) in certain directions exhibit unusual ghosting artifacts that cannot be eliminated with existing ghost removal methods. These artifacts have been related to a higherโ€order magnetic field perturbati

Gradient field switching as a source for
โœ Avshalom Shenhav; Haim Azhari ๐Ÿ“‚ Article ๐Ÿ“… 2004 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 261 KB

## Abstract Metallic implants, such as stents, have long been a concern in magnetic resonance imaging (MRI). In addition to safety issues, they are commonly associated with image artifacts. The mechanisms of radiofrequencyโ€ (RF) and susceptibilityโ€induced artifacts have been thoroughly investigated