Electrochemical inhibitor injection for control of reinforcement corrosion in carbonated concrete
✍ Scribed by J. Kubo; S. Sawada; C. L. Page; M. M. Page
- Publisher
- John Wiley and Sons
- Year
- 2008
- Tongue
- German
- Weight
- 192 KB
- Volume
- 59
- Category
- Article
- ISSN
- 0947-5117
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
This paper describes preliminary investigations into the effectiveness of an electrochemical method of injecting organic base corrosion inhibitors into carbonated concrete containing embedded steel bars on which corrosion had been pre‐initiated. The corrosion inhibitors studied were pure compounds of ethanolamine (pK~a~ ∼ 9.5) and guanidine (pK~a~ ∼ 13.6). They were injected from aqueous solutions placed in contact with the surfaces of the water‐saturated concrete specimens by applying constant current electrolysis between anodes located within the inhibitor solutions and embedded steel bars acting as cathodes. The concentration profiles of the inhibitors penetrating the concrete cover were examined and the influence of the various treatments on the corrosion rates of the embedded steel bars was estimated by linear polarisation resistance measurements, carried out repeatedly during exposure of the treated specimens to cyclic wetting and drying over several months. The stability of the concentration profiles of the inhibitors was evaluated and measurements of corrosion weight losses of the steel bars were also undertaken on completion of the exposure regimes. It was found that the specimens treated with the inhibitors showed significantly reduced corrosion when compared with untreated control specimens that were subjected to similar exposure.
📜 SIMILAR VOLUMES
## Abstract Inhibition of the corrosion of reinforced steel in concrete in 0.5 M NaCl by Arghel extract has been studied employing different electrochemical techniques in conjunction with optical images photo. Potential‐time measurements showed that introducing of Arghel extract into concrete shift
## Abstract Corrosion inhibitors are used to prevent chloride‐induced corrosion in reinforced concrete structures. Since performance of commercial organic inhibitors is only partially satisfactory, a 7‐year long research has been carried out in order to set‐up a new organic inhibitive mixture, able
## Abstract The time of incubation (TI) and chloride threshold (CT) necessary to initiate corrosion of reinforcement steel are crucial variables to predict the useful life of an infrastructure in any model. For black steel there is a great amount of data in the bibliography. However, for galvanized
## Abstract Corrosion sensors were devised to develop a system whereby the depth of chloride permeation from concrete surfaces can be monitored non‐destructively on a real‐time basis using such sensors embedded in cover concrete of reinforced concrete structures. The proposed corrosion sensors were
## Abstract The quantification of active corrosion rate of steel in concrete structures through nondestructive methods is a crucial task for scheduling maintenance/repair operations and for achieving accurate service life predictions. Measuring the polarization resistance of corroding systems and u