𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Electrocardiographic changes and arrhythmias following percutaneous atrial septal defect and patent foramen ovale device closure

✍ Scribed by Jonathan N. Johnson; Michelle L. Marquardt; Michael J. Ackerman; Samuel J. Asirvatham; Guy S. Reeder; Allison K. Cabalka; Frank Cetta; Donald J. Hagler


Publisher
John Wiley and Sons
Year
2011
Tongue
English
Weight
85 KB
Volume
78
Category
Article
ISSN
1522-1946

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Objectives: To compare pre‐ and post‐procedure electrocardiograms (ECGs) in a large cohort of patients after percutaneous closure of atrial septal defect (ASD) and patent foramen ovale (PFO). Background: Percutaneous device closure of ASD or PFO is commonplace. Conduction and rhythm anomalies associated with percutaneous device placement have been reported. Methods: We reviewed records for all patients who underwent percutaneous device closure of ASD or PFO at our institution from 1999 to 2008. Pre‐procedure ECG and Holter studies were compared to available short term (<2 months after placement) and intermediate follow‐up (>2 months) ECG or Holter. Results: Pre‐ and post‐procedural ECGs were available in 610 patients (305 females, average age 50 ± 18.1 years, range 1–91 years, 384 PFO, 184 ASD, 42 with multiple defects, mean device size 16 mm, range 5–38 mm). We report an incidence of 5.2% (32/610) of arrhythmias in the 4 months following device placement, including 29 patients with atrial tachyarrhythmias (ATs, 22 fibrillation, 7 flutter), 1 with junctional tachycardia, and 2 with heart block. Among other findings, the average P‐wave duration was increased on intermediate follow‐up as compared to early follow‐up (P < 0.001). Development of new‐onset 1st degree AV Block after the procedure was associated with an increased risk of ATs post‐procedure (P < 0.0001). Conclusion: We report a low risk of clinically significant post‐procedure arrhythmias after device placement. Clinically significant heart block occurred in only two patients (0.3%). Changes in several markers of atrial conduction were found, suggesting an effect of device closure on intra‐atrial conduction. © 2011 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Iatrogenic atrial septal defect, erosion
✍ Bernhard Meier 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 179 KB 👁 2 views

## Abstract Iatrogenic atrial septal defects are described in 2 patients. They occurred after implantation of Amplatzer occluders to close a patent foramen ovale. While device erosions to the extra‐atrial space have been described, erosion induced atrial septal defects are a new medical entity. The