Hematopoietic stem cells, collected by leukapheresis from peripheral blood. can be used as an alternative to autologous bone marrow transplantation following high-dose chemotherapy as treatment of several malignancies. We compared the ability of the Cobe Spectra and the Fenwal CS3000 to collect peri
Effects of whole blood flow rates on mononuclear cell yields during peripheral blood stem cell collection using fenwal CS 3000 plus
โ Scribed by Jeong-Shi Lin; Edwin A. Burgstaler; Alvaro A. Pineda; Morie A. Gertz
- Publisher
- John Wiley and Sons
- Year
- 1995
- Tongue
- English
- Weight
- 452 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0733-2459
No coin nor oath required. For personal study only.
โฆ Synopsis
It is generally assumed that using high whole blood flow rates (WBFR), 80 ml/min, during peripheral blood stem cell (PBSC) collection on the Fenwal CS 3000 Plus blood cell processor will result in higher yields of mononuclear cells (MNC) than using lower WBFR (50 ml/min). To test this assumption, we retrospectively studied 129 PBSC procedures on 17 patients in a multiple myeloma protocol comparing MNC yield, as well as red blood cell (RBC), granulocyte, and platelet (Plt) content, of four average WBFR groups. Standard PBSC procedures were performed using modified procedure 1, interface offset 100, anticoagulant (AC) ratio of 11: 1, small volume collection chamber, and a processing time of 4 hours. After correcting for AC volume used, the volume processed was divided by 240 minutes to obtain the average WBFR. WBFRs were separated into 4 groups of 4 W 9 , 5&59, 6 M 9 , and 70-79 m l h i n .
When compared to the highest flow rate group (70-79 m h i n ) , the three lower flow rate groups had significantly higherMNCyieldsof16.226.9, 13.1 2 5 . l , a n d 1 1 . 5 t 4 . 7 X lO',respectively,ascomparedto8.926.1 X lo9 MNC for the 70-79 m h i n group. There was no significant difference in granulocyte yield which ranged from 1.6 2 2. I to 4.5 * 4.8 X lo9.
2.2 ml than all three other groups with 16.2 2 4.3, 16.6 & 4.0, and 17.9 * 4.2 ml, respectively, but high average WBFR collected significantly less platelets (0.6 k 0.7 x 10" versus 1.9 * 1.0, 1.5 * 0.9, and 1.2 2 0.9, respectively). Incidence of citrate reactions increased as flow rates increased, 6%, 18%, 30%, and 33%, respectively. We conclude that using a lower average WBFR during PBSC collection actually produced significantly more MNC, with equivalent granulocytes, less RBC, but more platelets than the high average WBFR.
There were also significantly more RBC in the 70-79 ml/min group with 21.1