Effects of sterilization processes on NiTi alloy: Surface characterization
β Scribed by Thierry, B. ;Tabrizian, M. ;Savadogo, O. ;Yahia, L'H.
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 997 KB
- Volume
- 49
- Category
- Article
- ISSN
- 0021-9304
No coin nor oath required. For personal study only.
β¦ Synopsis
Sterilization is required for using any device in contact with the human body. Numerous authors have studied device properties after sterilization and reported on bulk and surface modifications of many materials after processing. These surface modifications may in turn influence device biocompatibility. Still, data are missing on the effect of sterilization procedures on new biomaterials such as nickeltitanium (NiTi). Herein we report on the effect of dry heat, steam autoclaving, ethylene oxide, peracetic acid, and plasma-based sterilization techniques on the surface properties of NiTi. After processing electropolished NiTi disks with these techniques, surface analyses were performed by Auger electron spectroscopy (AES), atomic force microscopy (AFM), and contact angle measurements. AES analyses revealed a higher Ni concentration (6-7 vs. 1%) and a slightly thicker oxide layer on the surface for heat and ethylene oxide processed materials. Studies of surface topography by AFM showed up to a threefold increase of the surface roughness when disks were dry heat sterilized. An increase of the surface energy of up to 100% was calculated for plasma treated surfaces. Our results point out that some surface modifications are induced by sterilization procedures. Further work is required to assess the effect of these modifications on biocompatibility, and to determine the most appropriate methods to sterilize NiTi.
π SIMILAR VOLUMES
Alloys of NiTi have gained popularity in biomedical applications ; however, Ni is known to cause toxic and allergic reactions in the body, and concerns have been expressed regarding the materialΓs biocompatibility. In this study, coupons of equiatomic NiTi were prepared by four methods, namely, mech
## Abstract Autoclave sterilization of paperβwrapped stainless steel implants resulted in slight general surface corrosion and crystalline contamination. Such artifacts may produce microanodes which induce local tissue reactions, thereby lowering the pH and further activating the corrosion process.
## Abstract The purpose of the present study is to thoroughly understand the influence of crystallographic texture on the stressβstrain asymmetric behavior of polycrystalline NiTi shape memory alloy under tension and compression. To do this, a 3D thermoβmechanical model has been implemented in a fi
## Abstract The impact of femoral head surface roughness on wear of Ξ³βirradiation sterilized (3 MRad in nitrogen, crosslinked) and nonsterilized (not crosslinked) UHMWPE acetabular cups has been evaluated. Gravimetric wear testing was performed in a hip joint simulator for 2 Γ 10^6^ cycles. CoCrMo