Effects of selective pulses on the measurement of T2 and apparent diffusion in multiecho MRI

✍ Scribed by S. Majumdar; J. C. Gore


Publisher
John Wiley and Sons
Year
1987
Tongue
English
Weight
488 KB
Volume
4
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


The effects of using spatially selective and nonuniform radiofrequency pulses on the apparent T2 of a train of multiple echoes have been calculated by computer simulation. It is demonstrated that the use of selective pulses produces errors in estimates of T2 in imaging experiments because regions of the slice are effectively off resonance and therefore receive spin rotations less than in an ideal case. Components of the transverse magnetization that are incompletely rotated by 180" refocusing pulses produce longitudinal components that are later returned to the transverse plane and add to subsequent echoes. These socalled ghost components influence the precise value of T2 estimated, but even when completely removed the resultant estimate is too short. The apparent T2 is influenced by the magnitude of the nutation angle inhomogeneity across the slice and paradoxically is not always more accurate with larger numbers of echoes. The reduction of apparent T2 caused by increasing the slice-selection gradient across a thin slab of material replicates the effects previously ascribed to diffusion and affords an alternative explanation for these without recourse to motion of the Spins. 0 1987 Academic press, Inc.


πŸ“œ SIMILAR VOLUMES


Effects of slice selection and diffusion
✍ S. T. S. Wong; M. S. Roos πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 362 KB

This study examines slice selection and diffusion as sources of systematic error in Tz estimates obtained from imaging experiments. The selective refocusing pulses in a multislice, two-echo, spin-warp experiment cause slice profiles of sequential echoes to change in shape. This results in bias in T2

Effect of disease progression on liver a
✍ Stephan W. Anderson; Hernan Jara; Al Ozonoff; Michael O'Brien; James A. Hamilton πŸ“‚ Article πŸ“… 2011 πŸ› John Wiley and Sons 🌐 English βš– 781 KB

## Abstract ## Purpose: To evaluate the effects of hepatic fibrosis on ADC and T~2~ values of ex vivo murine liver specimens imaged using 11.7 Tesla (T) MRI. ## Materials and Methods: This animal study was IACUC approved. Seventeen male, C57BL/6 mice were divided into control (n = 2) and experim

In vivo quantification of T1, T2, and ap
✍ Junjie Chen; Qing Wang; Huiying Zhang; Xiaoxia Yang; Jian Wang; Bruce A. Berkowi πŸ“‚ Article πŸ“… 2008 πŸ› John Wiley and Sons 🌐 English βš– 620 KB

## Abstract MRI has recently been used for noninvasive examination of retinal structure and function in rats and cats. However, the advantages of quantitative high‐resolution MRI of retina from mice have not yet been explored. In the present study, __T__~1~ and __T__~2~ relaxation time constants an

Errors in the measurements of T2 using m
✍ S. Majumdar; S. C. Orphanoudakis; A. Gmitro; M. O'Donnell; J. C. Gore πŸ“‚ Article πŸ“… 1986 πŸ› John Wiley and Sons 🌐 English βš– 547 KB

The accurate estimation of the spin-spin relaxation time T2 is an important goal in magnetic resonance imaging particularly because it can be used for quantitative tissue characterization. The spin-spin relaxation time T2 may be estimated using multiecho pulse sequences, but the accuracy of the esti

Effect of shot number on the calculated
✍ Masoud Shiehmorteza; Claude B. Sirlin; Tanya Wolfson; Anthony Gamst; Andre E. So πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 328 KB

## Abstract ## Purpose To show the signal intensity varies with shot number in diffusion‐weighted (DW) echo‐planar imaging (EPI) and affects apparent diffusion coefficient (ADC) calculation. ## Materials and Methods This prospective study was performed on 35 adult patients and 20 volunteers. Mea