The current safety standards for radiofrequency and microwave exposure do not limit the peak power of microwave pulses for general or occupational exposures. While some biological effects, primarily the auditory effect, depend on pulsed microwaves, hazards associated with very high peak-power microw
Effects of high peak power microwaves on the retina of the Rhesus monkey
โ Scribed by Shin-Tsu Lu; Satnam P. Mathur; Bruce Stuck; Harry Zwick; John A. D'Andrea; John M. Ziriax; James H. Merritt; Gerard Lutty; D. Scott McLeod; Mary Johnson
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 664 KB
- Volume
- 21
- Category
- Article
- ISSN
- 0197-8462
No coin nor oath required. For personal study only.
โฆ Synopsis
We studied the retinal effects of 1.25 GHz high peak power microwaves in Rhesus monkeys. Preexposure fundus photographs, retinal angiograms, and electroretinograms (ERG) were obtained to screen for normal ocular structure and function and, after exposure, as endpoints of the study. Histopathology of the retina was an additional endpoint. Seventeen monkeys were randomly assigned to receive sham exposure or pulsed microwave exposures. Microwaves were delivered anteriorly to the face at 0, 4.3, 8.4, or 20.2 W/kg spatially and temporally averaged retinal specific absorption rates (R-SAR). The pulse characteristics were 1.04 MW ( approximately 1.30 MW/kg temporal peak R-SAR), 5.59 micros pulse length at 0, 0.59, 1. 18, and 2.79 Hz pulse repetition rates. Exposure was 4 h per day and 3 days per week for 3 weeks, for a total of nine exposures. The preexposure and postexposure fundus pictures and angiograms were all within normal limits. The response of cone photoreceptors to light flash was enhanced in monkeys exposed at 8.4 or 20.2 W/kg R-SAR, but not in monkeys exposed at 4.3 W/kg R-SAR. Scotopic (rod) response, maximum (combined cone and rod) response, and Naka-Rushton R(max) and log K of scotopic b-waves were all within normal range. Retinal histopathology revealed the presence of enhanced glycogen storage in photoreceptors among sham (2/5), 8.4 W/kg (3/3), and 20.2 W/kg (2/5) exposed monkeys, while enhanced glycogen storage was not observed in the 4.3 W/kg (0/4) exposed group. Supranormal cone photoreceptor b-wave was R-SAR dependent and may be an early indicator of mild injury. However no evidence of degenerative changes and ERG depression was seen. We concluded that retinal injury is very unlikely at 4 W/kg. Functional changes that occur at higher R-SAR are probably reversible since we saw no evidence of histopathologic correlation with ERG changes. Bioelectromagnetics 21:439-454, 2000. Published 2000 Wiley-Liss, Inc.
๐ SIMILAR VOLUMES
Behavioral effects of high-peak-power microwave pulses on Wistar rats were studied by operant schedules. Each of twelve rats that had been trained to press a lever to receive food pellets was assigned randomly in groups of four to three different schedules of reinforcement: fixed-ratio (FR), variabl
This study explored the effects of restraint by females other than the mother on the vocalizations of infant rhesus macaques (Macaca mulatta) in a captive social setting. In this species, females are very attracted to young infants and will frequently approach, groom, and hold the infant. Incompeten
Certain types of inanimate environmental enrichment have been shown to positively affect the behavior of laboratory primates, as has housing them in appropriate social conditions. While social housing is generally advocated as an important environmental enhancement, few studies have attempted to mea