𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Effects of gold coating on experimental implant fixation

✍ Scribed by Kasra Zainali; Gorm Danscher; Thomas Jakobsen; Stig S. Jakobsen; Jørgen Baas; Per Møller; Joan E. Bechtold; Kjeld Soballe


Publisher
John Wiley and Sons
Year
2009
Tongue
English
Weight
195 KB
Volume
88A
Category
Article
ISSN
1549-3296

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Insertions of orthopedic implants are traumatic procedures that trigger an inflammatory response. Macrophages have been shown to liberate gold ions from metallic gold. Gold ions are known to act in an antiinflammatory manner by inhibiting cellular NF‐κB–DNA binding and suppressing I‐κ B‐kinase activation. The present study investigated whether gilding implant surfaces augmented early implant osseointegration and implant fixation by its modulatory effect on the local inflammatory response. Ion release was traced by autometallographic silver enhancement. Gold‐coated cylindrical porous coated Ti6Al4V implants were inserted press‐fit in the proximal part of tibiae in nine canines and control implants without gold inserted contralateral. Observation time was 4 weeks. Biomechanical push‐out tests showed that implants with gold coating had ∼50% decrease in mechanical strength and stiffness. Histomorphometrical analyses showed gold‐coated implants had a decrease in overall total bone‐to‐implant contact of 35%. Autometallographic analysis revealed few cells loaded with gold close to the gilded implant surface. The findings demonstrate that gilding of implants negatively affects mechanical strength and osseointegration because of a significant effect of the released gold ions on the local inflammatory process around the implant. The possibility that a partial metallic gold coating could prolong the period of satisfactory mechanical strength, however, cannot be excluded. © 2008 Wiley Periodicals, Inc. J Biomed Mater Res, 2009


📜 SIMILAR VOLUMES


The effect of enzymatically degradable I
✍ James E. Ho; Thomas A. Barber; Amarjit S. Virdi; Dale R. Sumner; Kevin E. Healy 📂 Article 📅 2007 🏛 John Wiley and Sons 🌐 English ⚖ 294 KB 👁 1 views

## Abstract Short‐term osseointegration of orthopedic implants is critical for the long‐term stability of the implant–bone interface. To improve initial implant stability, one strategy under consideration involves the presentation of adhesion ligands on the implant surface to stimulate bone regener

Biomechanical implant fixation of CoCrMo
✍ Stig S. Jakobsen; Jorgen Baas; Thomas Jakobsen; Kjeld Soballe 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 349 KB

## Abstract The use of CoCrMo in orthopedic surgery is not new, and CoCrMo (cobalt–chromium–molybdenum) is well tolerated. Nevertheless, the alloy is still considered less biocompatible than titanium. We therefore wanted to explore the biocompatibility of CoCrMo by investigating the biomechanical i

No effect of a type I collagen gel coati
✍ M. Svehla; P. Morberg; W. Bruce; W.R. Walsh 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 345 KB

## Abstract Uncemented joint replacement with a variety of substrate materials, structures, and coatings are commonplace in arthroplasty. Even with specialized surgical preparation of bone, intimate contact between the implant and host bone may not always be achieved. This study evaluated the __in

No effect of hydroxyapatite particles in
✍ O. Rahbek; S. Kold; K. Bendix; S. Overgaard; K. Soballe 📂 Article 📅 2005 🏛 John Wiley and Sons 🌐 English ⚖ 319 KB 👁 1 views

## Abstract The influence of wear debris on bone healing around orthopedic implants is debated. Hydroxyapatite (HA) particles and polyethylene (PE) particles have been shown to have a negative effect on osteoblast cultures __in vitro__. The present study investigated the __in vivo__ effects of HA a

Corrosion effects of three sterilization
✍ Sandrik, J. L. ;Wragg, L. E. 📂 Article 📅 1970 🏛 John Wiley and Sons 🌐 English ⚖ 203 KB

## Abstract Autoclave sterilization of paper‐wrapped stainless steel implants resulted in slight general surface corrosion and crystalline contamination. Such artifacts may produce microanodes which induce local tissue reactions, thereby lowering the pH and further activating the corrosion process.

Biologic effects of surface roughness an
✍ Savarino, L. ;Fini, M. ;Ciapetti, G. ;Cenni, E. ;Granchi, D. ;Baldini, N. ;Greco 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 406 KB

The concomitant influence of surface roughness and fluorhydroxyapatite (FHA) coating of titanium (Ti) implants on bone response was investigated. For this purpose, titanium screw-shaped implants with a lower degree (Y371) and a higher degree (TiPore300) of surface roughness, coated with FHA and unco