A series of tests was carried out to assess the performance of transit time ultrasonic flowmeters in both good and disturbed flow conditions. In Phase I, eleven commercial meters were tested in good flow conditions. These meters included single-beam wetted and clamp-on designs and a dual-beam wetted
Effects of flow disturbance on an ultrasonic gas flowmeter
✍ Scribed by E. Håkansson; J. Delsing
- Publisher
- Elsevier Science
- Year
- 1992
- Tongue
- English
- Weight
- 610 KB
- Volume
- 3
- Category
- Article
- ISSN
- 0955-5986
No coin nor oath required. For personal study only.
✦ Synopsis
A series of tests are carried out to assess the effects of flow disturbance on a small dimension ultrasonic gas flowmeter. Flow disturbances generated by cone couplings, and single and double elbows are investigated. Measurements with a 100 D straight pipe upstream with a smooth connection to the meter body are used as a reference. Our measurements show that the symmetrical disturbance produced by a cone coupling at a 12 D distance from the transducer path does not impair the performance of the flowmeter. An asymmetrical disturbance, such as a single or a double elbow at the same distance, seems generally to give an underestimation of the flow velocity, resulting in reading errors of-1% or worse. Measurements with straight pipes of 10 D, 20 D, 40 D and 80 D between the disturbance and the flowmeter have also been made showing that 10 D can cause an overestimation of flow velocity. Increasing the length of the straight pipe generally decreases the error. More than 80 D straight pipe between the disturbance and the flowmeter is required to give a result within +-1% of reference conditions. The angle between the elbow plane and the transducer plane is changed from 0 to 315 ° in 45 ° steps. The meter error is plotted as a function of inlet angle, showing a clear relationship between these values.
📜 SIMILAR VOLUMES
## Abstract The structure of gas–liquid two‐phase flow is investigated in order to establish a reliable criterion for the development of disturbance waves and droplets considering the effects of liquid viscosity. The structure of the gas–liquid interface and the flow rate of droplets entrained in g
Flow disturbances associated with the physical presence and sink action of two types of engine-cylinder-gas sampling probes were investigated in a steady-flow rig. Flow visualization and comparisons of concentration profiles obtained with an isokinetic probe and the two engine-type probes showed tha
The sensitivity of a membrane-covered oxygen gas sensor under the influence of gas flow has been tested experimentally. As the oxygen sensor is placed in different positions relative to the air-pump and gas flow meter, the effect of gas flow-rate on the response of the sensor is notable. By choosing