Effects of cord motion on diffusion imaging of the spinal cord
β Scribed by Hardave S. Kharbanda; David C. Alsop; Adam W. Anderson; Giovanni Filardo; David B. Hackney
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 354 KB
- Volume
- 56
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Measurement of diffusion and its dependence on direction has become an important tool for clinical and research studies of the brain. Diffusion imaging of the spinal cord may likewise prove useful as an indicator of tissue damage and axonal integrity; however, it is more challenging to perform diffusion imaging in the cord than in the brain. Here we report a study of the effects of motion on singleβshot fast spin echo (FSE) diffusion tensor imaging (DTI) of the spinal cord. Diffusion imaging was performed at four different times in the cardiac cycle both without and with velocity compensation of the diffusion gradients. Uncompensated diffusion images demonstrated substantial signal loss artifacts in the cord that were strongly dependent on the delay after the pulseβoximeter trigger. Quantitative diffusion analysis was also strongly affected by this motion artifact. The use of flowβcompensated gradients helped to restore normal signal in the cord, especially at particular trigger delays. Theoretical arguments suggest that improved spatial resolution may help eliminate this signal loss. Even with higher spatial resolution, motionβrelated signal attenuation may still occur in diffusion imaging of pathologies that alter the motion of the cord. However, this same cord motion may contain diagnostically valuable information when probed using appropriate diffusion imaging approaches. Magn Reson Med, 2006. Β© 2006 WileyβLiss, Inc.
π SIMILAR VOLUMES
## Abstract MRI, is a key tool for noninvasive spinal cord lesion analysis; however, accurate, quantitative methods for this analysis are lacking. A new, multistep, multidimensional approach, utilizing the classification expectation maximization algorithm, is proposed for MRI segmentation of spinal
Apparent diffusion tensor (ADT) measurements on the spinal cord using a pulsed-field-gradient (PFG) multi-shot echo-planar imaging (EPI) sequence are presented. In a study of 10 healthy volunteers, the obtained rotationally invariant anisotropy information is compared to the results obtained by the
## Abstract Spinal cord (SC) motion is thought to be the dominant source of error in current diffusion and spinal functional MRI (fMRI) methods. However, until now, such motion has not been well characterized in three dimensions. While previous studies have predominantly examined motion in the supe