𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Effects of contamination on ion mobility detection after gas chromatography

✍ Scribed by Michael A. Baim; Herbert H. Hill Jr.


Book ID
104146772
Publisher
Elsevier Science
Year
1984
Tongue
English
Weight
701 KB
Volume
299
Category
Article
ISSN
1873-3778

No coin nor oath required. For personal study only.

✦ Synopsis


The ion mobility detector is a device that can be used for the selective, ultratrace detection of organic compounds after capillary gas chromatography. It is the only gas chromatographic detector which does not require heteroatomic compounds for selective response, yet concern is often expressed over its quantitative capabilities. Being a secondary ionization device, competitive charge transfer reactions from unseparated compounds or detector gas contamination may decrease the accuracy of measurement. This paper investigates the effects of both electronegative and electropositive contaminants on the detector's response. In general, it was found that contamination of the detector did affect response but no more severely than in conventional detectors such as the electron-capture detector or the flame ionization detector.


πŸ“œ SIMILAR VOLUMES


Detection limits of an ion mobility dete
✍ Robert H. St. Louis; William F. Siems; Herbert H. Hill Jr. πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 661 KB

## Abstract A method for setting gating parameters is presented that maximizes response in ion mobility detection following capillary gas chromatography. The method requires knowledge of the drift times of the product ion or ions of interest and the drift times of the reactant ions. These values ar

Electron capture ion mobility spectromet
✍ St. Louis, Robert H. ;Hill, Herbert H. πŸ“‚ Article πŸ“… 1990 πŸ› John Wiley and Sons 🌐 English βš– 447 KB

## Abstract This paper reports the first investigation of electron capture ion mobility spectrometry as a detection method for capillary gas chromatography. In previous work with negative ion mobility detection after gas chromatography, the principal reactant ion species were O~2~^βˆ’^ or hydrated O~

Detection of gram-negative Erwinia herbi
✍ A. Peter Snyder; Waleed M. Maswadeh; Ashish Tripathi; Jacek P. Dworzanski πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons βš– 842 KB

Aerosol particulate species of the gram-negative bacterium Erwinia herbicola (EH) were detected by stand-alone, analytical instrumentation in an outdoor western United States desert test site. The device consisted of an aerosol collector interfaced to a quartz-tube pyrolysis-gas chromatography/ion-m