## Abstract ## Purpose To examine the impact of spatial resolution and respiratory motion on the ability to accurately measure atherosclerotic plaque burden and to visually identify atherosclerotic plaque composition. ## Materials and Methods Numerical simulations of the Bloch equations and vess
Effects of breathing and cardiac motion on spatial resolution in the microscopic imaging of rodents
✍ Scribed by Wilfried Maï; Cristian T. Badea; Charles T. Wheeler; Laurence W. Hedlund; G. Allan Johnson
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 509 KB
- Volume
- 53
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
One can acquire high‐resolution pulmonary and cardiac images in live rodents with MR microscopy by synchronizing the image acquisition to the breathing cycle across multiple breaths, and gating to the cardiac cycle. The precision with which one can synchronize image acquisition to the motion defines the ultimate resolution limit that can be attained in such studies. The present work was performed to evaluate how reliably the pulmonary and cardiac structures return to the same position from breath to breath and beat to beat across the prolonged period required for MR microscopy. Radiopaque beads were surgically glued to the abdominal surface of the diaphragm and on the cardiac ventricles of anesthetized, mechanically ventilated rats. We evaluated the range of motion for the beads (relative to a reference vertebral bead) using digital microradiography with two specific biological gating methods: 1) ventilation synchronous acquisition, and 2) both ventilation synchronous and cardiac‐gated acquisitions. The standard deviation (SD) of the displacement was ≤100 μm, which is comparable to the resolution limit for in vivo MRI imposed by signal‐to‐noise ratio (SNR) constraints. With careful control of motion, its impact on resolution can be limited. This work provides the first quantitative measure of the motion‐imposed resolution limits for in vivo imaging. Magn Reson Med 53:858–865, 2005. © 2005 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To evaluate the effect of varying spectral resolution on image quality of high spectral and spatial resolution (HiSS) images. ## Materials and Methods Eight women with suspicious breast lesions and six healthy volunteers were scanned using echo‐planar spectroscopic imaging
## Abstract Several aspects of blipped echo‐planar imaging (EPI) are treated mathematically. An expression relating the necessary readout gradient strength and sampling time to the spatial resolution and readout duration is derived. It is shown how the net spatial resolution may be limited by the o
## Abstract The original article to which this Erratum refers was published in Journal of Magnetic Resonance Imaging (2002) 18(4) 442–448.
__k-t__ Sensitivity-encoded (__k-t__ SENSE) acceleration has been used to improve spatial resolution, temporal resolution, and slice coverage in first-pass cardiac magnetic resonance myocardial perfusion imaging. This study compares the effect of investing the speed-up afforded by __k-t__ SENSE acce
## Abstract The purpose of our study was to evaluate the effect of respiratory motion on the image contrast of T2‐weighted fast spin‐echo (FSE) images of the liver as well as the reduction of motion artifact using respiratory triggering of the data acquisition. We imaged the livers of 10 healthy vo