𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy

✍ Scribed by Matt A. Bernstein; Sean B. Fain; Stephen J. Riederer


Book ID
102373571
Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
448 KB
Volume
14
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Standard, MR spin-warp sampling strategies acquire data on a rectangular k-space grid. That method samples data from the "corners" of k-space, i.e., data that lie in a region of k-space outside of an ellipse just inscribed in the rectangular boundary. Illustrative calculations demonstrate that the data in the corners of k-space contribute to the useful resolution only if an interpolation method such as a zero-filled reconstruction is used. The consequences of this finding on data acquisition and data windowing strategies are discussed. A further implication of this result is that the spatial resolution of images reconstructed with zero-filling (but without radial windowing) is expected to display angular dependence, even when the phase- and frequency-encoded resolutions are identical. This hypothesis is experimentally verified with a slit geometry phantom. It is also observed that images reconstructed without zero-filling do not display the angular dependence of spatial resolution predicted solely by the maximal k-space extent of the raw data. The implications of these results for 3D contrast-enhanced angiographic acquisitions with elliptical centric view ordering are explored with simulations.


πŸ“œ SIMILAR VOLUMES


High spatial and temporal resolution car
✍ Peter Kellman; Christophe Chefd'hotel; Christine H. Lorenz; Christine Mancini; A πŸ“‚ Article πŸ“… 2009 πŸ› John Wiley and Sons 🌐 English βš– 871 KB

## Abstract Cine MRI is used for assessing cardiac function and flow and is typically based on a breath‐held, segmented data acquisition. Breath holding is particularly difficult for patients with congestive heart failure or in pediatric cases. Real‐time imaging may be used without breath holding o

The effects of different input data and
✍ Markus Venohr; Horst Behrendt; Winfrid Kluge πŸ“‚ Article πŸ“… 2005 πŸ› John Wiley and Sons 🌐 English βš– 538 KB

## Abstract This paper focuses on the influences of different data sources, and the variation in spatial resolution of input data and analysis, on the calculated nutrient emissions using the conceptual model MONERIS. MONERIS calculates both nitrogen and phosphorus emissions from point and diffuse s