Effect of using local arterial input functions on cerebral blood flow estimation
✍ Scribed by Cory Lorenz; Thomas Benner; Chloe Joan Lopez; Hakan Ay; Ming Wang Zhu; Hannu Aronen; Jari Karonen; Yawu Liu; Juho Nuutinen; A. Gregory Sorensen
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 720 KB
- Volume
- 24
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To investigate a previously developed method for perfusion‐weighted MRI (PWI) cerebral blood flow (CBF) estimation that uses local arterial input functions (AIFs) in stroke patients, and determine its ability to correct delay and/or dispersion (D/D) errors.
Materials and Methods
Analysis was performed on dynamic susceptibility contrast data from 36 stroke patients, and CBF maps were calculated with global‐ and local‐AIF techniques using standard SVP based methods. The ratios of these maps were calculated and the mean ratios were calculated for voxels with both normal and abnormal time to peak or width. The locations of the voxels with high locally‐defined to globally‐defined CBF ratios were also mapped and the average underlying concentration‐time curves for these voxels were calculated.
Results
The ratio of CBF estimates based on local AIFs to global AIFs was on average increased for D/D voxels. The voxels in which this ratio was high were commonly concentrated in the ipsilateral hemisphere, and these voxels also displayed underlying concentration‐time curves that showed delay or dispersion. Conversely, there were no such findings based on high globally‐defined to locally‐defined CBF ratios.
Conclusion
The local‐AIF technique results in an increase in the calculated CBF values for tissues with D/D, consistent with a reduction in the errors associated with D/D. J. Magn. Reson. Imaging 2006. © 2006 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract An accurate determination of the arterial input function (AIF) is necessary for quantification of cerebral blood flow (CBF) using dynamic susceptibility contrast‐enhanced magnetic resonance imaging. In this study, we developed a method for obtaining the AIF automatically using fuzzy c‐m
## Purpose: Erectile dysfunction (ed) is the persistent inability to achieve or maintain an erection sufficient for satisfactory sexual performance. oral use of sildenafil citrate is effective in the treatment of ed. although the effects of sildenafil citrate have been investigated in several syste
## Abstract The lipid mediator prostaglandin E~2~ (PGE~2~) exhibits diverse biologic activity in a variety of tissues. Four PGE~2~ receptor subtypes (EP1–4) are involved in various physiologic and pathophysiologic conditions, but differ in tissue distribution, ligand‐binding affinity, and coupling
Arterial spin tagging techniques originally used the one-compartment Kety model to describe the dynamics of tagged water in the brain. The work presented here develops a more realistic model that includes the contribution of tagged water in the capillary bed and accounts for the finite time required
## Abstract Previous modeling studies have predicted that a significant fraction of the signal in arterial spin labeling (ASL) experiments originates from labeled water in the capillaries. Provided that the relaxation times in blood and tissue are similar, ASL data can still be analyzed with the co