To assess the effect of sulphite on the oxidative metabolism of human neutrophils, chemiluminescence (CL) measurements were performed using lucigenin and luminol as chemiluminigenic probes. Lucigenin-dependent CL was used for measuring superoxide anion (0;) production, and luminol-dependent CL was u
Effect of the geometry of microfabricated flow reactors on chemiluminescent detection of epinephrine with lucigenin
β Scribed by Tamio Kamidate; Tomoyuki Kaide; Hirofumi Tani; Eiji Makino; Takayuki Shibata
- Publisher
- John Wiley and Sons
- Year
- 2001
- Tongue
- English
- Weight
- 137 KB
- Volume
- 16
- Category
- Article
- ISSN
- 1522-7235
- DOI
- 10.1002/bio.665
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Three types of flow reactors with different lengths (12β126β mm) and widths (0.4β2.0β mm) of channel were made on the silicon chip by microfabrication techniques for the chemiluminescent (CL) detection of epinephrine (EP) with lucigenin (Luc). The volume of each CL reactor was about 10β Β΅L. A solution containing EP and Luc and a solution containing NaOH and periodate were injected successively into each inlet of the CL reactor in the range 20β100β Β΅L/min with a pressureβdriven flow system. The intensity of light emission was dependent on the geometry of the flow reactors. These results could be explained in terms of the differences in the diffusion length of the reactants in the flow reactors. The maximum light emission were linearly correlated, with the concentrations of EP over the range from the detection limit of 5.0β Γβ 10^β8^β mol/L up to 5.0β Γβ 10^β6^β mol/L on the use of the CL reactor with the most promising geometry. Copyright Β© 2001 John Wiley & Sons, Ltd.
π SIMILAR VOLUMES
The unstable plastic flow caused by the Portevin-Le Chatelier effect is studied experimentally. Non-local effects due to strain heterogeneity are addressed by comparing the statistical and multifractal properties of tension and compression deformation curves of an AlMg alloy. Power-law statistical d
## Abstract The highβenergy intermediates generated in the reaction of bis(2,4,6βtrichlorophenyl)oxalate (TCPO) with H~2~O~2~ can excite electronically different fluorophores with a high quantum yield in organic solvents. We have previously applied this peroxyoxalate chemiluminescent reaction to th
A highly selective flow-injection system was developed for the determination of methanol. The system consisted of three immobilized enzymes with luminol chemiluminescence detection. First, methanol was oxidized in the presence of alcohol ozidase to yield formaldehyde and hydrogen peroxide. The hydro