𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Effect of structure on the electron-capture negative ionization mass spectrometric response of steroids

✍ Scribed by Helen K. Mayer; William Reusch; J. Throck Watson


Publisher
John Wiley and Sons
Year
1992
Tongue
English
Weight
676 KB
Volume
27
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The key to enhanced electron‐capture negative ion mass spectrometry (ECNI‐MS) response of ketosteroids is extensive α,β‐unsaturation. Combinations of double bonds, carbonyl groups, epoxides and halogens within a steroid nucleus were correlated with their ECNI responses. The greatest ECNI responses result from extensive conjugation, such as the linearly conjugated 4‐ene‐3,6‐dione system and the cross‐conjugated 1,4‐diene‐3,11‐dione system. In general, an epoxy ketosteroid has a relative response 40 times greater than that of its corresponding enone. In an α‐halo ketone, an axial halogen substitution will increase the relative response by an order of magnitude, but an equatorial halogen substituent will not affect the response. The fragmentation of ketosteroids as related to ECNI response is discussed.


📜 SIMILAR VOLUMES


Effect of ammonia on the response of the
✍ Abdel-Rehim, Mohamed ;Kamel, Mohamed ;Hassan, Moustapha 📂 Article 📅 1995 🏛 John Wiley and Sons 🌐 English ⚖ 309 KB

## Abstract The effect of ammonia on the electron capture detector (ECD) response has been investigated. Nitrogen with different ammonia concentrations (5–20%) was used as make‐up gas. Compared to pure nitrogen, the ECD response decreased when the ammonia concentration in the make‐up gas was 5%. Ho

Mass spectrometric characteristics of de
✍ J. Björklund; P. Tollbäck; C. Östman 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 139 KB

## Abstract The mass spectrometric properties of ^12^C‐and ^13^C‐labeled decabromodiphenyl ether (BDE‐209) in the low‐resolution mass spectrometry electron capture negative ionization mode (ECNI‐MS) is described in detail and are compared with those of polybrominated diphenyl ethers (PBDEs) with a

On the significance of [M−HCl]− fragment
✍ Walter Vetter; Bernd Luckas 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 127 KB 👁 2 views

The response factors of compounds of technical toxaphene vary significantly in GC/ECNI-MS. The response of 2-endo,3-exo,5-endo,6-exo,8,8,9,10-octachlorobornane (B8-1412) was twice as high as in GC/ECD if compared with 2-endo,3-exo,5-endo,6-exo,8,8,10,10-octachlorobornane (B8-1413 or Parlar #26). One

Further studies on a site-specific hydro
✍ G. K.-C. Low; A. M. Duffield 📂 Article 📅 1985 🏛 John Wiley and Sons 🌐 English ⚖ 463 KB

Further studies have demonstrated that the site-specific hydrogen transfer process involved in the formation of the m Iz 145 anion of P-hydroxyamine pentafluoropropionate (PFP) derivatives observed under electron capture negative ion chemical ionization conditions occurs when the two functional grou