𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Effect of microtextured surfaces on the performance of percutaneous devices

✍ Scribed by X. F. Walboomers; J. A. Jansen


Publisher
John Wiley and Sons
Year
2005
Tongue
English
Weight
435 KB
Volume
74A
Category
Article
ISSN
1549-3296

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Along the percutaneous part of implantable devices, like (semi‐)permanent catheters, epithelial downgrowth can occur. This process can eventually lead to implant loss. Various treatments for the catheter surface have been proposed, to improve their performance. The purpose of the current study was to investigate the effect of a microgroove pattern on the tube surface, on epithelial downgrowth. Catheterlike implants were made of silicone tubes, with anchoring cuffs made of titanium‐fiber mesh. A thin sheet of silicone with microgrooves was applied on the tubes. Two types of texturing were used, a square groove of 10 ΞΌm wide and 1 ΞΌm deep; or a V‐shaped groove of 40 ΞΌm wide. The grooves were directed either along the long axis of the catheter tube (grooves perpendicular to the skin surface) or circling around the catheter (grooves directed parallel to the skin surface). As controls, catheters with a smooth outer surface were used. Implants were placed in 30 rats, with a follow‐up period of 9 weeks. During this time, animals were inspected biweekly, and catheter exit sites were evaluated using a scoring system. At the end of the 9‐week period the implants and surrounding tissues were processed for histological evaluation. For the clinical evaluation of the exit sites, no statistical differences were found between the study groups. Histologically, epithelial downgrowth was observed for all samples. The histomorphometrical measurements showed that there were no differences in downgrowth between the smooth and parallel‐grooved catheters. However, there was increased epithelial downgrowth along the catheters with grooves perpendicular to the skin. In conclusion, a grooved microtexture can direct epithelial tissue ingrowth, but this study found no beneficial effects of the guidance phenomenon. Β© 2005 Wiley Periodicals, Inc. J Biomed Mater Res, 2005


πŸ“œ SIMILAR VOLUMES


Effect of nebulizer type and antibiotic
✍ Allan Weber; Greg Morlin; Morty Cohen; Judy Williams-Warren; Bonnie Ramsey; Arno πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 167 KB

We compared the performance of selected ultrasonic and jet nebulizers when aerosolizing several antibiotic formulations to determine optimum combinations for delivery of a respirable antibiotic aerosol. Three ultrasonic devices were tested: the UltraNeb 99/100, the UltraAIR and the Aerosonic. The re