Effect of hip protectors in falls on the hip
✍ Scribed by J. B. Lauritzen; K. Hindsø; S. Sonne-Holm; M. M. Pedersen; B. Lund
- Publisher
- Springer-Verlag
- Year
- 1996
- Tongue
- English
- Weight
- 138 KB
- Volume
- 6
- Category
- Article
- ISSN
- 0937-941X
No coin nor oath required. For personal study only.
📜 SIMILAR VOLUMES
An anatomical hip model has been developed to simulate the impact load on the hip of a falling person wearing a hip protector. The hip consists of an artificial pelvis made of aluminium, linked by a ball-and-socket joint to an anatomically shaped steel femur (thigh bone). The femur is embedded in si
Compliant flooring represents a promising but understudied strategy for reducing impact force and hip fracture risk due to falls in high-risk environments such as nursing homes, hospitals, gymnasiums, and senior centers. We conducted ''pelvis release experiments'' with young women (n ¼ 15) to determ