## Abstract The effect of anaesthesia on the rate of bone blood flow in the rabbit was studied. Two estimates of bone blood flow were performed, using 15 ΞΌm radioactively labelled microspheres, in three groups of rabbits. The first group was anaesthetised and the interval between the two estimates
Effect of fracture fixation on cortical bone blood flow
β Scribed by Stephen R. Smith; James T. Bronk; Patrick J. Kelly
- Publisher
- Elsevier Science
- Year
- 1990
- Tongue
- English
- Weight
- 734 KB
- Volume
- 8
- Category
- Article
- ISSN
- 0736-0266
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
Because internal and external fixation devices alter blood flow, and thus the transport of nutrients to the cortical bone of a healing fracture, we studied the effects of a fluted intrameduilary rod (IMR), a halfβframe external fixator (EF), and a compression plate (PL) on the cortical bone directly adjacent to the fracture site at 4 and 48 h and 14 and 90 days after fixation. Three specific areas of cortical bone were studied: endosteal cortex, periosteal cortex, and subplate cortex (cortical bone under the compression plate). The fractures fixed with IMR had the lowest blood flow at all time periods studied. At 4 h, the difference between IMR and PL or EF was statistically significant in the endosteal cortex (p < 0.01 or p < 0.05, respectively); also, the difference between the IMR and EF in the subplate cortical bone region was significant (p < 0.05). At 14 days, the blood flow to the endosteal cortex was still significantly lower with IMR than with EF (p < 0.025). At 90 days, the blood flow to the subplate region of cortical bone was significantly (p < 0.02) higher with PL than with IMR but there was no significant difference in bone remodeling with the different fixation devices.
π SIMILAR VOLUMES
## Abstract The distribution of tibial blood flow was measured by injecting approximately (600β1000) X 10^3^ 15 ΞΌ microspheres, labelled with either tinβ113 (^113^Sn) or cobaltβ57 (^57^Co) into femoral arteries of five mature greyhounds. The diaphyseal cortex, stripped of periosteum and devoid of m
## Abstract We investigate the effect of specimen geometry on the ultimate tensile strength of cortical bone measured by a tensile test. This article is motivated by the fact that there is no clear consensus in the literature on a suitable specimen shape for cortical bone testing. We consider three
Sixteen bone blocks from two freshly amputated legs were used to study the effect of CO2 laser on cortical bone. They were divided into two groups. In Group I, the blocks were treated with CO2 laser using 1 mm spot (focused mode). In Group II, they were treated with CO2 laser using 3 mm spot (defocu