𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Effect of biopassive and bioactive surface-coatings on the hemocompatibility of membrane oxygenators

✍ Scribed by Anja K. Zimmermann; Norbert Weber; Hermann Aebert; Gerhard Ziemer; Hans P. Wendel


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
275 KB
Volume
80B
Category
Article
ISSN
1552-4973

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Postoperative complications associated with cardiopulmonary bypass (CPB) surgery and extracorporeal circulation (ECC) procedures are still a major clinical issue. Improving the hemocompatibility of blood contacting devices used for ECC procedures may ameliorate various postpump syndromes. In a simulated CPB model using human blood, we investigated the hemocompatibility, fibrinogen adsorption, and platelet receptor (GPIIb‐IIIa) binding capacity of surface‐modified membrane oxygenators (Jostra Quadrox). Three groups were compared: (i) biopassive protein coatings (SafeLine®), (ii) bioactive heparin coatings (BioLine®), and (iii) noncoated controls. During the 2 h recirculation period, plasma concentrations of activation markers for platelets (β‐thromboglobulin), inflammation (elastase), complement (C5a), and coagulation (prothrombin fragment 1+2, thrombin–antithrombin III) were lower in the groups with biopassive and bioactive coatings compared to the noncoated group (p < 0.01). These parameters did not significantly differ between the two surface‐coated groups, except for complement activation: C5a levels were higher in the biopassive group compared to the bioactive group (p < 0.01). Moreover, surface‐coated oxygenators showed less fibrinogen adsorption, GPIIb‐IIIa binding, and platelet/leukocyte adhesion (p < 0.01). We assume that fewer fibrinogen and platelet receptor molecules bound to the surface‐coated oxygenator surfaces results in fewer platelet adhesion and activation, which will significantly contribute to the improved hemocompatibility of the biopassive and bioactive oxygenators. Our results suggest that the application of bioactive oxygenators (BioLine®) during CPB surgery may reduce postoperative complications for the patient more effectively than biopassive oxygenators (SafeLine®). © 2006 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2007


📜 SIMILAR VOLUMES


Effect of nitrogen and oxygen incorporat
✍ Meng Chen; Shigemasa (Gem) Osaki; Paul O. Zamora; Mila Potekhin 📂 Article 📅 2003 🏛 John Wiley and Sons 🌐 English ⚖ 306 KB 👁 1 views

## Abstract To investigate the influence of nitrogen and oxygen incorporated into __N__‐trimethylsilylallyamine (TMSAA) plasma coating on heparin binding to the surfaces, four types of monomer combinations were utilized. Those combinations include TMSAA alone, TMSAA mixed with nitrogen (TMSAA + N~2

The effect ofin vitro modeling condition
✍ Radin, S. ;Ducheyne, P. ;Rothman, B. ;Conti, A. 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 581 KB

Using one parametric variation in solution composition, this paper documents that the surface reactions on bioactive glass (BG) 45S5 are exquisitely dependent upon the modeling conditions. The solutions used were 0.05M tris hydroxymethyl aminomethane/HCl (tris buffer), tris buffer complemented with