Dynamic T1 estimation of brain tumors using double-echo dynamic MR imaging
✍ Scribed by Yoshiyuki Ishimori; Hirohiko Kimura; Hidemasa Uematsu; Tsuyoshi Matsuda; Harumi Itoh
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 924 KB
- Volume
- 18
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To assess the clinical utility of a new method for real‐time estimation of T1 during the first pass of contrast agent by using this method to examine brain tumors.
Materials and Methods
The multi‐phase spoiled gradient‐echo pulse sequence using the double‐echo magnetic resonance (MR) technique was modified. In the first half of the pulse sequence, the flip angle was varied systematically. Then, static T1 values were calculated using differences in MR signal intensities between different flip angles. In the latter half of this sequence, changes in absolute T1 were calculated using differences in signal intensities before and after injection of contrast agent. The double‐echo MR data were used to minimize the T2* effect. Five cases of neurinoma and seven cases of meningioma were examined. Changes in T1 during the first pass of contrast agent were compared between neurinoma and meningioma.
Results
Changes in absolute T1 were clearly demonstrated on the parametric map. Although the changes in absolute T1 during the first pass of contrast agent did not allow differentiation between the two types of tumors, the mean gradient after the first pass was statistically higher for neurinoma than for meningioma (P < 0.05; meningioma, 0.011 ± 0.012 second^−1^/second; neurinoma, 0.034 ± 0.020 second^−1^/second).
Conclusion
The present method appears to be useful for estimation of dynamic T1 changes in brain tumors in clinical settings. J. Magn. Reson. Imaging 2003;18:113–120. © 2003 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract Echo‐planar imaging has been used to observe the dynamics of Gd‐DTPA uptake in brain tumors. It has been possible to examine both vascular uptake and diffusion across the blood‐brain barrier in a single experiment, by using the IR‐MBEST echo‐planar sequence which combines a high tempora
## Abstract A technique for estimation of the longitudinal relaxation time of a large homogeneous object with an acquisition time of 4s or less was developed by combining spatially selective rf tagging pulses with a T1‐weighted magnetization‐prepared gradient‐echo sequence. Multiple 5‐mm‐wide tagge
## Abstract Dynamic MR images of the passage of gadopentetate dimeglumine through the kidneys of normal rats are obtained using a dual gradient‐echo sequence. The amplitudes of gradient echoes are defined by local T1 and T2\* values in the tissue. The ratio of these amplitudes, primarily defined by