Dynamic MR digital subtraction angiography using contrast enhancement, fast data acquisition, and complex subtraction
✍ Scribed by Yi Wang; Donald L. Johnston; Jerome F. Breen; John Huston Iii; Clifford R. Jack; Paul R. Julsrud; Michael J. Kiely; Bernard F. King; Stephen L. Riederer; Richard L. Ehman
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 793 KB
- Volume
- 36
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A dynamic MR angiography technique, MR digital subtraction angiography (MR DSA), is proposed using fast acquisition, contrast enhancement, and complex subtraction. When a bolus of contrast is injected into a patient, data acquisition begins, dynamically acquiring a thick slab using a fast gradient echo sequence for 10–100 s. Similar to x‐ray DSA, a mask is selected from the images without contrast enhancement, and later images are subtracted from the mask to generate angiograms. Complex subtraction is used to overcome the partial volume effects related to the phase difference between the flowing and stationary magnetization in a voxel. Vessel signal is the enhancement of flow magnetization resulting from the contrast bolus. MR DSA was performed in 28 patients, including vessels in the lungs, brains, legs, abdomen, and pelvis. All targeted vessels were well depicted with MR DSA. Corresponding dynamic information (contrast arrival time t~a~ and duration of the arterial phase t~av~) was measured: t~a~/t~av~ = 3.4/4.7 s for the lung, 10.3/4.9 s for the brain, 12.8/19.3 for the aorta, 15.2/12.6 s for the leg. MR DSA can provide dynamic angiographic images using a very short acquisition time.
📜 SIMILAR VOLUMES
## Abstract Contrast‐enhanced magnetic resonance angiography is routinely performed using parallel imaging to best capture the first pass of contrast material through the target vasculature, followed by digital subtraction to suppress the appearance of unwanted signal from background tissue. Both p
In this study, our purpose was to compare the high-resolution contrast-material-enhanced three-dimensional subtraction MR angiography with conventional angiography for occlusive disease in the pelvic and lower extremity arteries. A three-dimensional fast-imaging with steady precession (FISP) sequenc
## Abstract ## Purpose: To compare the image qualities of unenhanced electrocardiographically (ECG)‐gated fast spin‐echo magnetic resonance digital subtraction angiography (MRDSA) using a short echo‐spacing three‐dimensional (3D) sequence, known as sampling perfection with application‐optimized co