Ambient and forced vibration tests were carried out on the Beauharnois bridge, a unique, 177-m combined suspension and cable-stayed structure near Montreal, Canada. A rehabilitation program was completed on the bridge during which the deck was completely rebuilt with an orthotropic slab on two steel
DYNAMIC INVESTIGATION OF A REPAIRED CABLE-STAYED BRIDGE
β Scribed by GENTILE, C.; MARTINEZ Y CABRERA, F.
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 460 KB
- Volume
- 26
- Category
- Article
- ISSN
- 0098-8847
No coin nor oath required. For personal study only.
β¦ Synopsis
The theoretical and experimental investigation of a cable-stayed bridge after major repair is described in this paper. Strengthening mainly involved the suspension system (originally with prestressed concrete stays) which was retrofitted by means of external tendons. Full-scale tests were conducted to measure the dynamic response of the repaired system; the experimental program included both traffic-induced and free vibration measurements. A total of 16 vertical frequencies and mode shapes were identified in the frequency range of 0-10 Hz. In the theoretical study, vibration modes involving deck, towers and cables were determined by using finite element models which accounted for the strengthening effects. Two-and three-dimensional models were used so that the importance of three-dimensional modes was estimated as well. The experimental results were compared to natural frequencies and mode shapes computed using theoretical models. For most modes the measured and predicted modal parameters compare well, especially for the vertical modes involving in-phase motion of the stays.
π SIMILAR VOLUMES
A description of an experimental investigation involving the study of the dynamic interaction between the cables and the deck/towers system in cable-stayed bridges is presented. The work was carried out on a physical model of a cable-stayed bridge (the Jindo Bridge, in South Korea), whose characteri
The present paper describes an investigation of the e!ect of dynamic cable interaction with the deck and towers in the seismic response of a cable-stayed bridge. This study involved shaking table tests performed on a physical model of Jindo bridge, in order to validate two alternative numerical mode
## Abstract The trafficβinduced variability in the dynamic properties of a cableβstayed bridge is investigated using ambient vibration measurements. Under a relatively steady wind and temperature environment, the ambient vibration test was conducted on the bridge with normal traffic conditions and