## Abstract The major drawback to quantitative perfusion imaging using arterial spin labeling (ASL) techniques is the need to acquire two images (tag and control), which must be subtracted in order to obtain a perfusionโweighted image. This can potentially result in misregistration artifacts, espec
Dynamic imaging of the compliant perfusion of the lungs
โ Scribed by J. J. P. Lima; J. A. Rafael; M. F. Botelho
- Publisher
- Springer
- Year
- 1986
- Tongue
- English
- Weight
- 417 KB
- Volume
- 12
- Category
- Article
- ISSN
- 0340-6997
No coin nor oath required. For personal study only.
โฆ Synopsis
A method for the study of the dynamics of the perfusion of the compliant vascular tree of the lungs using in vivo labelled 99mTc red cells and ECG gating is presented. Following blood pool labelling, posterior, ECG gated gamma camera images were acquired in time intervals of about 40 ms for 1,000-2,000 cardiac cycles. The images show the lungs plus the heart and great vessels. The image sequence containing the periodic variation of the blood activity in the lungs during the cardiac cycle is analyzed to obtain volume curves and functional images of the amplitude and phase of the lung perfusion. The interference of the heart and great vessels with the left lung can be avoided by excluding the superimposed areas in the ROIs with the sacrifice of part of the left lung. This technique allows dynamic visualization of the perfusion process in the compliant arterial and venous vascular trees of the lungs. The results obtained with this method in normals and some pathologies are discussed.
๐ SIMILAR VOLUMES
## Abstract ^99m^Tcโlabelled macroaggregated albumin (MAA) is the radiopharmaceutical routinely used for perfusion lung scans. However MAA formulations contain excipients of biological origin, that may potentially cause allergic hypersensitivity in patients. The aim of this study was to prepare a n
## Abstract Recent studies have demonstrated the potential of dynamic contrastโenhanced magnetic resonance imaging (MRI) describing pulmonary perfusion. However, breathing motion, susceptibility artifacts, and a low signalโtoโnoise ratio (SNR) make automatic pixelโbyโpixel analysis difficult. In th
## Abstract Cardiac dynamic magnetic resonance imaging (MRI) after contrast media injection suffers from motion induced by free breathing during acquisition. This work presents an automated approach for motion correction of the heart. The registration is based on the multipass/multiresolution itera