## Abstract ## Purpose To compare Gadomer, a macromolecular magnetic resonance (MR) contrast agent, and gadolinium diethylenetriamine pentaacetic acid (Gd‐DTPA) for quantifying angiogenesis in tissue‐engineered bladder constructs. ## Materials and Methods Constructs enhanced with vascular endoth
Dynamic Gd-DTPA enhanced MRI as a surrogate marker of angiogenesis in tissue-engineered bladder constructs: A feasibility study in rabbits
✍ Scribed by Hai-Ling Margaret Cheng; Jun Chen; Paul S. Babyn; Walid A. Farhat
- Book ID
- 102907727
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 577 KB
- Volume
- 21
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To evaluate the potential of dynamic contrast‐enhanced magnetic resonance imaging (DCE‐MRI) to assess angiogenesis in tissue‐engineered bladder constructs in a blinded animal study, and compare different analysis approaches and their correlation with microvessel density (MVD).
Materials and Methods
Constructs fortified with vascular endothelial growth factor (VEGF) for enhanced vascularity were grafted onto the bladder in nine rabbits. DCE‐MRI of Gd‐DTPA uptake was performed and analyzed using Tofts' model, the area under the concentration time curve (AUC), and the uptake slope. DCE‐MRI parameters were compared to MVD determined with CD31 immunohistochemistry.
Results
Significantly increased MVD was found in the high VEGF group (20 ng/g of tissue) but not at low VEGF (10 ng/g) (2.3× increase, P = 0.035 vs. 1.1× over control). Enhanced permeability at low VEGF was suggested by elevated K^trans^, but overall correlation to MVD was poor. Significant correlation to MVD was obtained with AUC~8min~ (r = 0.705, P = 0.034). Furthermore, AUC~8min~ provided the most precise discrimination between different VEGF preparations and was the only parameter to show a significant increase (P = 0.0058) consistent with MVD changes at high VEGF.
Conclusion
Findings support DCE‐MRI for evaluating angiogenesis in bladder constructs and suggest vessel changes other than density. Future studies should incorporate larger contrast agents and permeability assessment to devise an optimal DCE‐MRI strategy. J. Magn. Reson. Imaging 2005;21:415–423. © 2005 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract The purpose of this study was to evaluate the suitability of a macromolecular MRI contrast agent (paramagnetic nanoparticles, PNs) for the characterization of tumor angiogenesis. Our aim was to estimate the permeability of PNs in developing tumor vasculature and compare it with that of