## AhEtmct-This paper presents an experimental study of metal-solution potential distributions in fiowthrough porous electrodes of fixed beds of spherical conducting particles. The distributions are determined when the electrodes are working at the limiting diffusion current. They are shown to be
Distribution of potential in a porous electrode under conditions of flow electrolysis
โ Scribed by R.E. Sioda
- Publisher
- Elsevier Science
- Year
- 1971
- Tongue
- English
- Weight
- 540 KB
- Volume
- 16
- Category
- Article
- ISSN
- 0013-4686
No coin nor oath required. For personal study only.
โฆ Synopsis
A simplified theoretical model of the electric potential distribution in a porous electrode, working with limiting current and with flowing solution, is described. The model is based on several approximations, eg uniform flow velocity in the porous electrode. Equations are derived for the potential distribution in the solution filling the porous electrode, and for Ihe difference of the potentials in the solution between the front and rear ends of the electrode. The latter equation is checked experimentally for the process of the electroreduction of K,Fe(CN),.
An agreement between the theoretical model and the experimental data is obtained for a limited range of flow velocities.
๐ SIMILAR VOLUMES
A numerical model of flow-through porous electrodes is presented. This model simulates the distribution of potential and current density within a porous electrode. The model includes consideration of the electron transfer control regime of the electrode reaction, mass transport limitations and the f
Abshaet -The paper examines the influence of the relative electric conductivity of the solution and matrix phases on the potential distribution in flow-through porous electrodes working under limiting current conditions. The solution giving the potential distribution is deduced and is experimentally
A model for the use of multiple electrodes in cculometric cells is presented. It is shown that, by interconnecting the electrodes with appropriate external resistances, all of the electrodes can, in theory, be maintained at identical potentials. Some of the practicalities to be considered in designi