Direct stenting with a combined intravascular ultrasound-coronary stent delivery platform: A feasibility trial
✍ Scribed by Eric Eeckhout; Alexandre Berger; Christan Roguelov; Xavier Lyon; Christophe Imsand; Malika Fivaz-Arbane; Grégoire Girod; Edoardo De Benedetti
- Publisher
- John Wiley and Sons
- Year
- 2003
- Tongue
- English
- Weight
- 361 KB
- Volume
- 59
- Category
- Article
- ISSN
- 1522-1946
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
IVUS is considered as the most accurate tool for the assessment of optimal stent deployment. Direct stenting has shown to be a safe, efficient, and resource‐saving procedure in selected patients. In a prospective 1‐month feasibility trial, a new combined IVUS‐coronary stent delivery platform (Josonics Flex, Jomed, Helsingborn, Sweden) was evaluated during direct stenting in consecutive patients considered eligible for direct stenting. The feasibility endpoint was successful stent deployment without any clinical adverse event, while the efficacy endpoint was strategic adaptation according to standard IVUS criteria for optimal stent deployment at the intermediate phase (after a result considered angiographically optimal) and at the end of the intervention (after optimization according to IVUS standards). A total of 16 patients were successfully treated with this device without any major clinical complication. At the intermediate phase, optimal stent deployment was achieved in four patients only, while at the end only one patient had nonoptimal IVUS stent deployment. In particular, the minimal in‐stent cross‐section area increased from 6.3 ± 1.2 to 8.3 ± 2.5 mm^2^. These preliminary data demonstrate the feasibility of direct stenting with a combined IVUS‐stent catheter in selected patients and confirm the results from larger randomized trials on the impact of IVUS on strategic adaptations during coronary stent placement. Cathet Cardiovasc Intervent 2003;59:451–454. © 2003 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
This case report describes the intravascular ultrasound (IVUS) evaluation of a coronary artery aneurysm, developed in a stented segment within 6 mo after bailout stenting. Analysis of the IVUS images provides in vivo insights in the vessel-remodeling process after mechanical injury. The proximal ent
We evaluated the use of both intracoronary ultrasound (ICUS) information and unique balloon characteristics provided by a combined ICUS/variable diameter balloon catheter during coronary interventions to achieve the maximal residual lumen using the least number of devices. In 47 patients, 64 coronar