Direct observation of the formation of aromatic pollutants in waste incineration flue gases by on-line REMPI-TOFMS laser mass spectrometry
β Scribed by R. Zimmermann; H. J. Heger; A. Kettrup; U. Nikolai
- Book ID
- 105896427
- Publisher
- Springer
- Year
- 2000
- Tongue
- English
- Weight
- 302 KB
- Volume
- 366
- Category
- Article
- ISSN
- 1618-2650
No coin nor oath required. For personal study only.
π SIMILAR VOLUMES
We have applied a newly designed, mobile, resonance-enhanced multiphoton ionization (REMPI) time-of-flight mass spectrometer for real-time on-line emission analysis of flue gases from a technical waste incineration pilot plant. With one-color REMPI (laser wavelength: 248 nm), benzene, toluene, pheno
Mobile resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (REMPI-TOFMS) was applied for on-line detection of surrogates for polychlorinated dibenzo-p-dioxins/furans (PCDD/F) in the flue gas of an industrial hazardous waste incineration plant (thermal power: 22 MW). Convention