Heat transfer from a hot water layer to a heavier Freon 113 layer was studied in a cell in which each layer could be independently stirred to yield parallel or counter-flow. In the absence of boiling, the transfer rates can either be determined analytically, using the boundary layer model or correla
Direct contact heat transfer between immiscible liquid layers with simultaneous boiling and stirring
โ Scribed by G. Fortuna; S. Sideman
- Publisher
- Elsevier Science
- Year
- 1968
- Tongue
- English
- Weight
- 1004 KB
- Volume
- 23
- Category
- Article
- ISSN
- 0009-2509
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
Boiling heat transfer characteristics in liquid-liquid direct contact parallel flow of immiscible liquids were investigated. The effect of operating conditions and column specifications on the UA factor of heat transfer were determined and the following empirical correlation is proposed for conditio
This paper reports on an experimental study of the direct contact heat transfer between oil and water in turbulent pipe flow under nonboiling conditions. Data were taken by a new technique, namely, monitoring on a very fast response recorder the output of a small thermacouple placed in the two-phase