𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Direct comparison of myocardial perfusion cardiovascular magnetic resonance sequences with parallel acquisition

✍ Scribed by Jonathan C. Lyne; Peter D. Gatehouse; Ravi G. Assomull; Gillian C. Smith; Peter Kellman; David N. Firmin; Dudley J. Pennell


Publisher
John Wiley and Sons
Year
2007
Tongue
English
Weight
242 KB
Volume
26
Category
Article
ISSN
1053-1807

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Purpose

To directly compare the three main myocardial perfusion cardiovascular magnetic resonance (CMR) sequences incorporating parallel acquisition methods.

Materials and Methods

In 15 subjects (12 men, 57 ± 15.7 years) referred for diagnostic coronary angiography, we acquired first‐pass perfusion images (0.1 mmol/kg gadolinium‐DTPA) at rest and during adenosine (140 μg/kg/min) on three separate occasions using three sequences incorporating parallel acquisition methods and approximately equivalent spatiotemporal resolution: hybrid echo planar imaging (hEPI), steady‐state free precession (SSFP), and gradient echo imaging (GRE). We calculated the contrast‐to‐noise ratio (CNR) of each scan and blinded observers scored the presence and severity of artifacts (1, worst to 4, best), diagnostic confidence (0, low to 2, high), transmurality, area, and epicardial vessel territory of perfusion defects.

Results

CNR was greatest with SSFP and least with hEPI (13.15 vs 7.85 P < 0.001). The most artifacts were recorded with SSFP and least with hEPI (2.00 vs 3.03 P < 0.001). Observers were significantly more confident in reporting hEPI images (1.6 hEPI vs 0.9 SSFP, P < 0.001). Results for GRE were intermediate for all assessments.

Conclusion

The hEPI sequence scored best for diagnostic performance despite the SSFP sequence having greater CNR. This trial favors hEPI for clinical myocardial perfusion CMR and suggests CNR should not be the sole criterion used to gauge the best candidate sequence. J. Magn. Reson. Imaging 2007. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Parallel acquisition techniques in cardi
✍ Peter Hunold; Stefan Maderwald; Mark E. Ladd; Vladimir Jellus; Jörg Barkhausen 📂 Article 📅 2004 🏛 John Wiley and Sons 🌐 English ⚖ 385 KB 👁 1 views

## Abstract ## Purpose To compare image quality, artifacts, and signal‐to‐noise ratio (SNR) in cardiac cine TrueFISP magnetic resonance imaging (MRI) with and without parallel acquisition techniques (PAT). ## Materials and Methods MRI was performed in 16 subjects with a TrueFISP sequence (1.5 T;