𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Direct comparison of 3D spiral vs. Cartesian gradient-echo coronary magnetic resonance angiography

✍ Scribed by Peter Börnert; Matthias Stuber; René M. Botnar; Kraig V. Kissinger; Peter Koken; Elmar Spuentrup; Warren J. Manning


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
243 KB
Volume
46
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

While 3D thin‐slab coronary magnetic resonance angiography (MRA) has traditionally been performed using a Cartesian acquisition scheme, spiral k‐space data acquisition offers several potential advantages. However, these strategies have not been directly compared in the same subjects using similar methodologies. Thus, in the present study a comparison was made between 3D coronary MRA using Cartesian segmented k‐space gradient‐echo and spiral k‐space data acquisition schemes. In both approaches the same spatial resolution was used and data were acquired during free breathing using navigator gating and prospective slice tracking. Magnetization preparation (T~2~ preparation and fat suppression) was applied to increase the contrast. For spiral imaging two different examinations were performed, using one or two spiral interleaves, during each R‐R interval. Spiral acquisitions were found to be superior to the Cartesian scheme with respect to the signal‐to‐noise ratio (SNR) and contrast‐to‐noise‐ratio (CNR) (both P < 0.001) and image quality. The single spiral per R‐R interval acquisition had the same total scan duration as the Cartesian acquisition, but the single spiral had the best image quality and a 2.6‐fold increase in SNR. The double‐interleaf spiral approach showed a 50% reduction in scanning time, a 1.8‐fold increase in SNR, and similar image quality when compared to the standard Cartesian approach. Spiral 3D coronary MRA appears to be preferable to the Cartesian scheme. The increase in SNR may be “traded” for either shorter scanning times using multiple consecutive spiral interleaves, or for enhanced spatial resolution. Magn Reson Med 46:789–794, 2001. © 2001 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Assessment of aorto-iliac disease with m
✍ Shambhavi Venkataraman; Richard C. Semelka; Susan Weeks; Larissa Braga; Georgeta 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 English ⚖ 968 KB

## Abstract ## Purpose To evaluate magnetic resonance angiography (MRA) of the pelvis for the examination of the aorto‐iliac system using arterial phase 3‐D gradient echo and interstitial phase 2‐D fat‐suppressed spoiled gradient‐echo (SGE), with comparison to surgery and angiography. ## Material

Free-breathing 3D steady-state free prec
✍ Thanh D. Nguyen; Pascal Spincemaille; Matthew D. Cham; Jonathan W. Weinsaft; Mar 📂 Article 📅 2008 🏛 John Wiley and Sons 🌐 English ⚖ 379 KB 👁 1 views

## Abstract ## Purpose To compare the performance of the conventional diaphragm navigator (DNAV) and the recently developed cardiac fat navigator (FatNAV) in suppressing respiration‐induced cardiac motion in free‐breathing 3D balanced steady‐state free precession coronary MRA (SSFP CMRA). ## Mate

Direct comparison of sensitivity encodin
✍ R. Muthupillai; E. Douglas; S. Huber; B. Lambert; M. Pereyra; G.J. Wilson; S.D. 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 381 KB 👁 1 views

## Abstract ## Purpose: To assess the effect of attaining higher spatial resolution in contrast‐enhanced magnetic resonance angiography (MRA) of renal arteries using parallel imaging, sensitivity encoding (SENSE), by comparing the SENSE contrast‐enhanced (CE) MRA against a conventional CE‐MRA prot