Diffusion tensor imaging in evaluation of human skeletal muscle injury
✍ Scribed by Tatiana Zaraiskaya; Dinesh Kumbhare; Michael D. Noseworthy
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 588 KB
- Volume
- 24
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To explore the capability and reliability of diffusion tensor magnetic resonance imaging (DTI) in the evaluation of human skeletal muscle injury.
Materials and Methods
DTI of four patients with gastrocnemius and soleus muscles injuries was compared to eight healthy controls. Imaging was performed using a GE 3.0T short‐bore scanner. A diffusion‐weighted 2D spin echo echo‐planar imaging (EPI) pulse sequence optimized for skeletal muscle was used. From a series of axially acquired diffusion tensor images the diffusion tensor eigenparameters (eigenvalues and eigenvectors), fractional anisotropy (FA), and apparent diffusion coefficient (ADC) were calculated and compared for injured and healthy calf muscles. Two dimensional (2D) projection maps of the principal eigenvectors were plotted to visualize the healthy and pathologic muscle fiber architectures.
Results
Clear differences in FA and ADC were observed in injured skeletal muscle, compared to healthy controls. Mean control FA was 0.23 ± 0.02 for medial and lateral gastrocnemius (mg and lg) muscles, and 0.20 ± 0.02 for soleus (sol) muscles. In all patients FA values were reduced compared to controls, to as low as 0.08 ± 0.02. The ADC in controls ranged from 1.41 to 1.31 × 10^–9^ m^2^/second, while in patients this was consistently higher. The 2D projection maps revealed muscle fiber disorder in injured calves, while in healthy controls the 2D projection maps show a well organized (ordered) fiber structure.
Conclusion
DTI is a suitable method to assess human calf muscle injury. J. Magn. Reson. Imaging 2006. © 2006 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To demonstrate the feasibility of in vivo calf muscle fiber tracking in human subjects. ## Materials and Methods An EPI‐based diffusion tensor imaging (DTI) sequence with six‐direction diffusion gradient sensitization was implemented, and DT images were acquired at 3 Tesla
## Abstract Muscle architecture is the main determinant of the mechanical behavior of skeletal muscles. This study explored the feasibility of diffusion tensor imaging (DTI) and fiber tracking to noninvasively determine the in vivo three‐dimensional (3D) architecture of skeletal muscle in mouse hin
## Abstract In vivo longitudinal diffusion tensor imaging (DTI) of rodent spinal cord injury (SCI) was carried out over a period of eight weeks post‐injury. A balanced, rotationally invariant, alternating gradient polarity icosahedral diffusion encoding scheme was used for an unbiased estimation of
## Abstract This study demonstrates the feasibility of in vivo prostate diffusion tensor imaging (DTI) in human subjects. We implemented an EPI‐based diffusion‐weighted (DW) sequence with seven‐direction diffusion gradient sensitization, and acquired DT images from six subjects using cardiac gating