𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Diagnostic performance of stereotactic large core needle biopsy for nonpalpable breast lesions in routine clinical practice

✍ Scribed by Nicky Peters; Lidewij Hoorntje; Willem Mali; Inne Borel Rinkes; Petra Peeters


Publisher
John Wiley and Sons
Year
2007
Tongue
French
Weight
73 KB
Volume
122
Category
Article
ISSN
0020-7136

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

The COBRA (COre Biopsy after RAdiological localization) study showed that in a controlled study setting, stereotactic large core needle biopsy (LCNB) is as reliable for diagnosing nonpalpable breast lesions as open surgical biopsy. In the present study, we evaluated the diagnostic performance of stereotactic LCNB in routine clinical practice. Between February 2000 and June 2002, data on all patients (n = 955) with nonpalpable breast lesions referred for LCNB were collected. High risk underestimate rate, ductal carcinoma in situ (DCIS) underestimate rate and sensitivity rate after 2 years were calculated. The usefulness of the COBRA guidelines in clinical practice was determined. Nine hundred five successful biopsies were performed in 874 patients. Of the high‐risk lesions, 27% were found to be carcinomas on open biopsy, which is comparable to the results of the COBRA study (23%). The DCIS underestimate rate (28%) was higher than found in the COBRA study (17%). No carcinomas were missed after a follow‐up period of 2 years. Ninety‐six percent of patients were treated according to the COBRA guidelines. The diagnostic performance of stereotactic LCNB in patients with nonpalpable breast lesions seems to be comparable in a controlled study setting and routine clinical practice. © 2007 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Diagnostic accuracy of stereotactic larg
✍ Helena M. Verkooijen 📂 Article 📅 2002 🏛 John Wiley and Sons 🌐 French ⚖ 93 KB

## Abstract Stereotactic large‐core needle biopsy is increasingly applied for the diagnosis of nonpalpable breast disease. Our study examines whether this minimally invasive technique is sufficiently accurate to replace surgical breast biopsy. In a prospective multicenter study, 973 consecutive wom

Rate of insufficient samples for fine-ne
✍ Etta D. Pisano; Laurie L. Fajardo; John Tsimikas; Nour Sneige; William J. Frable 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 101 KB 👁 2 views

designed to evaluate fine-needle aspiration (FNA) of nonpalpable breast lesions performed by multiple operators using the same protocol.