Development of a three-part time-of-day electrical energy tariff
β Scribed by S. Shahnawaz Ahmed; A. K. M. Tafazzal Hossain
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 115 KB
- Volume
- 22
- Category
- Article
- ISSN
- 0363-907X
No coin nor oath required. For personal study only.
β¦ Synopsis
This paper presents an analytical technique for determining peak, offpeak and midpeak hours tariffs for various durations of these three periods. The technique considers the existing flat rate tariff, an hourly generation scenario of a utility on an average yearly demand day, the weighted average life time, annutised capital cost and fuel cost of base and peak load plants, and a break even point condition in the utility's revenue. The developed tariff has been applied to 30 representative industrial consumers served by the Bangladesh Power Development Board (BPDB) to estimate the minimum possible shift in consumption pattern and hence corresponding reduction in peak generation capacity requirement as well as peak time load shedding by BPDB.
π SIMILAR VOLUMES
In the analysis of short-and long-run effects of economic variables on energy use, co-integration techniques are promising candidates. These techniques were employed to develop an error correction model of annual US residential electricity demand. Equipment stock indices were compiled and the model