𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Development of a gas filter against wire chamber ageing for the MDT chambers in ATLAS

✍ Scribed by S. König; G. Herten; U. Landgraf; W. Mohr


Publisher
Elsevier Science
Year
2007
Tongue
English
Weight
231 KB
Volume
581
Category
Article
ISSN
0168-9002

No coin nor oath required. For personal study only.

✦ Synopsis


Drift chamber ageing is a serious concern for the operation of the Monitored Drift Tube chambers (MDT) in the ATLAS muon system. Therefore systematic studies of ageing effects have been carried out at the University of Freiburg. It has been shown that tiny contaminations with volatile silicon compounds, which are found in many components supplied by industry, cause a severe degradation of the drift tube performance. Since the ATLAS MDT system contains many thousands of commercial components the cleanliness of all parts cannot be guaranteed. Therefore gas filters with zeolites have been developed in Freiburg, which remove these impurities efficiently. They will be employed in the gas system for the MDT chambers.