𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Development and optimization of an LC-MS/MS-based method for simultaneous quantification of vitamin D2, vitamin D3, 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3

✍ Scribed by Jiri Adamec; Amber Jannasch; Jianjie Huang; Emily Hohman; James C. Fleet; Munro Peacock; Mario G. Ferruzzi; Berdine Martin; Connie M. Weaver


Publisher
John Wiley and Sons
Year
2010
Tongue
English
Weight
216 KB
Volume
34
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

✦ Synopsis


Simultaneous and accurate measurement of vitamin D and 25-hydroxyvitamin D in biological samples is a barrier limiting our ability to define ''optimal'' vitamin D status. Thus, our goal was to optimize conditions and evaluate an LC-MS method for simultaneous detection and quantification of vitamin D 2 , vitamin D 3 , 25-hydroxyvitamin D 2 and 25-hydroxyvitamin D 3 in serum. Extraction and separation of vitamin D forms were achieved using acetone liquid-liquid extraction and by a reversed phase C8 column, respectively. Detection was performed on a triple quadrupole tandem mass spectrometer (QQQ-MS/MS) equipped with atmospheric pressure photo ionization source. The LOQs for all analytes tested were 1 ng/mL for hydroxylated molecules and 2 ng/mL for the parent vitamin Ds. RSD at lower LOQ (2 ng/mL) and in medium (80 ng/mL) and high (200 ng/mL) quality control samples did not exceed 20 and 15% CV, respectively. Accuracy of the method for determination of hydroxylated molecules was also validated using National Institutes of Standards and Technology standard samples and found to be in the range of 90.9-111.2%. In summary, a sensitive and reproducible method is reported for simultaneous quantification of vitamin D 2 , vitamin D 3 , 25-hydroxyvitamin D 2 and 25hydroxyvitamin D 3 molecules in biological samples.


📜 SIMILAR VOLUMES


A specific LC/ESI-MS/MS method for deter
✍ Tatsuya Higashi; Masahiro Suzuki; Junji Hanai; Shinsuke Inagaki; Jun Zhe Min; Ka 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 260 KB 👁 1 views

A specific LC/ESI-MS/MS method for determination of 25-hydroxyvitamin D 3 in neonatal dried blood spots containing a potential interfering metabolite, 3-epi-25hydroxyvitamin D 3 Vitamin D deficiency in an infant is associated with a wide range of adverse health outcomes in later life. A method for t

A validated SIM GC/MS method for the sim
✍ Marios Spanakis; Ioannis S. Vizirianakis; Maria Mironidou-Tzouveleki; Ioannis Ni 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 347 KB 👁 2 views

## Abstract Dextromethorphan is used as a probe drug for assessing CYP2D6 and CYP3A4 activity __in vivo__ and __in vitro__. A SIM GC/MS method without derivatization for the simultaneous determination of dextromethorphan and its metabolites, dextrorphan, 3‐methoxymorphinan and 3‐hydroxymorphinan, i