✦ Synopsis


A sensitive method for the determination of vitamin (\mathrm{K}_{3}) using cathodic stripping voltammetry is presented. Using sodium sulfate as the supporting electrolyte at (\mathrm{pH} 1.70-1.85), a reductive peak ( (-0.64 \mathrm{~V}) vs SCE) is observed. The detection limit is (1 \times 10^{-9} \mathrm{M}). 1994 Academic Press, Inc.


πŸ“œ SIMILAR VOLUMES


Determination of mebendazole in urine by
✍ A.J. Conesa; J.M. Pinilla; L. HernΓ‘ndez πŸ“‚ Article πŸ“… 1996 πŸ› Elsevier Science 🌐 English βš– 477 KB

A cathodic stripping procedure has been developed for the determination of mebendazole. An 8 min accumulation time on a 0.1 M acetic acid/acetate pH=5 buffer solution gives rise to a detection limit of 3 x lo-l1 M. An extraction with ether has been developed for the determination of mebendazole in u

Determination of germanium(IV) by cataly
✍ Changqing Sun; Qian Gao; Jiubai Xi; Hongding Xu πŸ“‚ Article πŸ“… 1995 πŸ› Elsevier Science 🌐 English βš– 339 KB

Germanium(W) can be determined using adsorptive cathodic stripping voltammetry in the presence of 3,4-dihydroxybenzaldehyde (DHB). The sensitivity of the voltammetric technique was improved greatly by the addition of vanadium(W) to the sample. The reduction current of the adsorbed germanium(W)-DHB c

Determination of dimethoate in water by
✍ P. HernΓ‘ndez; Y. Ballesteros; F. GalΓ‘n; L. HernΓ‘ndez πŸ“‚ Article πŸ“… 1994 πŸ› John Wiley and Sons 🌐 English βš– 308 KB πŸ‘ 1 views

This article describes the direct determination of the pesticide dimethoate in river water in an alkaline medium through cathodic stripping voltammetry. By employing an alkaline media and accumulation potential of 30 mV, reduction peak appears at -0.7 V. The detection limit is 1 ng m1-I.

Determination of Se(IV) in On-Line Syste
✍ Mieczyslaw Korolczuk; Malgorzata Grabarczyk πŸ“‚ Article πŸ“… 2003 πŸ› John Wiley and Sons 🌐 English βš– 155 KB

## Abstract A sensitive and selective on‐line voltammetric procedure for determination of traces of Se(IV) is presented. The pulsed potential accumulation was proposed for minimization of interferences of surface active substances and foreign ions. The calibration plot was linear from 1Γ—10^βˆ’9^β€…mol