Determination of trace levels of transition metal ions in fermentation broth by ion-pair chromatography

โœ Scribed by Gerald Schuster; Werner A. Hampel


Publisher
Elsevier Science
Year
1992
Tongue
English
Weight
490 KB
Volume
258
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

โœฆ Synopsis


A method for the determmatlon of trace levels of transItion metal 1011s such as Fez+, Mn'+ and Zn2+ by hquld chromatography usmg reversed-phase Ion-pair separation, post-columu denva&atlon urlth 4_(2-pyrldylazo)resorcmol and spectrophotometnc detection at 520 and 540 nm IS described Even tugh levels of typlcal fermentation me&a constituents such as sugars and cltnc acid do not have a negatwe effect on the determmatlon The apphcatlon of the method to fig 1-l levels of Fe*+ and Mn*+ eons m atrlc acid fermentatum broth suffers from relatively high osclllatmg rmlse signals and unpredictable retention times, wluch IS caused by the cohmm capacity bemg exceeded at lugh concentrations of catIons such as K+, Mg2+ and Ca'+ and certam orgamc substances Dlgltal filtermg procedures were used to Improve the sIgnal-to-noise ratlo and correct peak ldentlficatlon was ensured by determmmg the absorption ratlo A5&As2,,


๐Ÿ“œ SIMILAR VOLUMES


Determination of metal ions as EDTA comp
โœ Jen-Fon Jen; Chih-Shih Chen ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 436 KB

A reversed-phase ion-pair liquid chromatographic method was developed for the determination of metal ions in aqueous solution. Metal ions were first chelated with EDTA, followed by injection into the chromatographic system. A reversed-phase C s column was used to separate the chelate ions with an el

Determination of Trace-Level Anions in H
โœ Yan Liu; Edward Kaiser; Nebojsa Avdalovic ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 68 KB

The use of the hydroxide eluents generated on-line by an automated hydroxide eluent generator system was compared with the use of hydroxide eluents prepared off-line in the ion chromatographic determination of trace inorganic and organic anions in high-purity water samples. The use of the hydroxide

Determination of Nitrate and Nitrite Ani
โœ M.J. Gonzalez; A.I. Valle; M.L. Marina ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 204 KB

The concentration of the inorganic anions nitrate and nitrite has been determined in the Guadalquivir river and the Donana National Park located in the Southwest of Spain. Reversed-phase ion pair liquid chromatography has been employed with tetrabutylammonium bromide as the counterion in the mobile