✦ Synopsis


A rapid and inexpensive method was developed to determine deuterium enrichment in body fluids. This is achieved by converting water into acetylene. To vacutainer tubes a small amount of calcium carbide is added. The tubes are evacuated and 25 pl of sample are injected through the stopper. The reaction takes place spontaneously at room temperature in a few seconds. Enrichment at mass 27 compared with mass 26 can be determined by continuous flow isotope ratio mass spectrometry without any interference from the carrier gas helium. A series of D,O samples diluted with increasing amounts of H,O is prepared at the time of measurement of the biological samples and the measured ratios are used to calculate the isotope dilution of the unknown. The relative error of the method is 1.6% when a dose of 25 ml kg-' is administered to the patient. The method was compared with two different methods in use in other laboratories, by a published method The means of the differences were -0.1 and 0.08 I, respectively, with standard deviations of 0.63 and 3.0. KEYWORDS: D,O; total body water; mass spectrometer


πŸ“œ SIMILAR VOLUMES


The analysis of trimethylamine in body f
✍ Graham S. King; Brain R. Pettit; James V. Leonard πŸ“‚ Article πŸ“… 1984 πŸ› John Wiley and Sons 🌐 English βš– 275 KB πŸ‘ 2 views

A simple, high throughput method of analysis of trimethylamine in body fluids has been developed to assist with the management of patients with the inherited metabolic disorder, trimethylaminuria. The headspace in sealed vials was analysed using perdeuterated (\*H,,)trimethylamine hydrochloride as a

A Simple and Rapid Colorimetric Method f
✍ Scott J. McGrance; Hugh J. Cornell; Colin J. Rix πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 105 KB πŸ‘ 2 views

However, there were significant correlations between the enthalpy involved and each of VAG maximum viscosity, breakdown, viscosity at 50 Β°C and set back (r = 0.53, P < 0.05; r = 0.49, P < 0.05; r = 0.62, P < 0.05; r = 0.65, P < 0.01, respectively). For RVA data, correlations were found only between

An Easy and Rapid Method for Determinati
✍ Dun-Shyurng Young; Huan-Yi Hung; Lilian Kao Liu πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 180 KB πŸ‘ 2 views

An easy and fast method using electrospray ionization mass spectrometry for determination of the stability constants (logK s ) of different metal-ion complexes with crown and lariat crown ethers has been developed. This method has been verified with known logK s by using either excess crown ether or