There are many dynamic methods for measuring the volumetric mass transfer coefficient. The "gas out-gas in" method can directly determine the volumetric m a s s transfer coefficient in a bioreactor system and provide estimates of the volumetric microbial oxygen uptake rate and the average oxygen sat
✦ LIBER ✦
Determination of the overall volumetric mass transfer coefficient kLa, by a temperature dependent change of gas solubility
✍ Scribed by Niels Thomas Eriksen; Jens Jørgen Lønsmann Iversen
- Publisher
- Springer-Verlag
- Year
- 1994
- Tongue
- English
- Weight
- 336 KB
- Volume
- 8
- Category
- Article
- ISSN
- 0951-208X
No coin nor oath required. For personal study only.
✦ Synopsis
The solubility of oxygen in the liquid phase of a bioreactor was changed by a ramp change of temperature, and k,a was determined from the resulting return to equilibrium of dissolved oxygen activity. The maximum k,a that can be measured by this method in a standard laboratory scale bioreactor is 14.5 he' corresponding to a temperature change rate of 320°C h-l.