𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Determination of oxygen and water vapour in modified atmosphere packages for meat sausages with and without an oxygen absorber

✍ Scribed by Göran Flodberg


Book ID
101288501
Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
130 KB
Volume
10
Category
Article
ISSN
0894-3214

No coin nor oath required. For personal study only.

✦ Synopsis


A gas chromatographic method has been developed that measures both the residual oxygen concentration and the level of relative humidity during the same run in modified atmosphere packages (N 2 /CO 2 ) with and without an oxygen absorber. A processed meat product with a high content of water served as the foodstuff in those packages. The chromatographic system consists mainly of a loop-injector connected to capillary columns coupled in series and a thermocouple detector. The introduction of an oxygen absorber seems to be attractive, since the concentrations obtained for the residual amount of oxygen in the packages with an oxygen absorber varied between 0.0043 and 0.029%. For packages without an absorber, the oxygen concentrations were much higher and fluctuated between 0.26 and 0.56%. The whole measuring period lasted for 27 days. The relative humidity, also a factor that can cause food deterioration, was 100%.


📜 SIMILAR VOLUMES