𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Determination of liposome size distribution by flow cytometry

✍ Scribed by Karola Vorauer-Uhl; Andreas Wagner; Nicole Borth; Hermann Katinger


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
176 KB
Volume
39
Category
Article
ISSN
0196-4763

No coin nor oath required. For personal study only.

✦ Synopsis


Background: An essential parameter that describes the quality of liposome suspensions is the mean size, respectively the size distribution. Currently several analytical methods including laser light scattering techniques (LLST) are being employed. Methods: Here we present an alternative technique using flow cytometry (FCM) to characterize uni-and polydisperse suspensions. As model liposomes preparations containing dipalmitoylphosphatidylcholine (DPPC) were used. A constant number of particles (1,500/s) in the fluid stream and a representative number of 10,000 particles of each sample was measured. Fluorescence-labeled latex beads were measured identically, and their side scatter signals were calibrated and correlated to the results obtained with liposome vesicles.

Results: Evaluation of the measurement and validation of the FCM results in comparison to LLST confirm the reliability of results obtained with our method. Latex beads in the range of 100 -1000 nm were used for calibration to classify liposomes. Altough measurement characteristics and calculation in both methods are basically different, very good agreement of the results was achieved. Conclusions: Demonstration of stability, reproducibility, and reliability of results make the employment of this method acceptable for an adequate routine analysis technique.


πŸ“œ SIMILAR VOLUMES


Genome size and GC-percent in vertebrate
✍ Alexander E. Vinogradov πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 125 KB πŸ‘ 1 views

Genome size and GC-percent were determined by means of a special method of DNA flow cytometry in 154 vertebrate species. For the total dataset, a highly significant positive correlation was found between both parameters. The overall distribution of points is not linear but triangular: a wide range o

Assessment of electroporation by flow cy
✍ J. Michie; D. Janssens; J. Cilliers; B.J. Smit; L. BΓΆhm πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 171 KB πŸ‘ 2 views
Noninvasive determination of genome size
✍ D.K. Lamatsch; C. Steinlein; M. Schmid; M. Schartl πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 202 KB πŸ‘ 1 views

## Background: In order to understand the evolutionary significance of single triploids among the mostly diploid Poecilia formosa we have developed a simple, noninvasive technique for DNA content and ploidy determination. Methods: From dorsal fin clips of 14 different fish species single cell suspe