Determination of entrained-air content in concrete mixes
โ Scribed by A. G. Shlaen
- Publisher
- Springer
- Year
- 1976
- Tongue
- English
- Weight
- 216 KB
- Volume
- 10
- Category
- Article
- ISSN
- 1570-1468
No coin nor oath required. For personal study only.
๐ SIMILAR VOLUMES
It is generally recognized that the air void structure of concrete is a critical parameter for the durability of concrete subjected to frost/thaw action and deicing salts. In the first part of this article an overview is given, of the different methods characterizing the air void structure in fresh
This paper deals with the effect of two different superplasticizers (Mighty and Melment) on the air-void system parameters produced by two different airentraining agents (NVR and Darex), when the superplasticizer is added some 40 minutes after the concrete has been batched and mixed. A significant d