Determination of aliphatic amines by cation-exchange chromatography with suppressed conductivity detection after solid phase extraction*

✍ Scribed by Innocenzo G. Casella; Giacomo A. Palladino; Michela Contursi


Publisher
John Wiley and Sons
Year
2008
Tongue
English
Weight
259 KB
Volume
31
Category
Article
ISSN
1615-9306

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

A sensitive method for the determination of underivatized aliphatic amines based on cation exchange chromatography coupled with suppressed conductivity detection scheme and solid phase extraction (SPE) procedure has been developed. A surface modified styrene divinylbenzene polymeric sorbent, based on a reversed‐phase (RP) and strong cation exchange (SCX) mixed mode was used as an active material for the SPE of amines. The conductometric capabilities of several aliphatic mono‐ and polyamines, expressed in terms of molar sensitivity (nS/μM), were determined. The LODs, obtained without the SPE treatment, ranged between 20 and 65 nM for putrescine and 2‐butylamine, respectively. The resulting calibration plots for the aliphatic amines were generally linear over about three orders of magnitude, with correlation coefficients >0.98. The LODs of amines decreased generally by one factor when SPE procedure, using BaCl~2~/H~2~SO~4~ eluents, has been adopted. The proposed SPE procedure, seems to offer good results in terms of preconcentration, recoveries and cleanup of samples. The proposed methodology was successfully tested for the quantitative determination of some biogenic amines in beer and tuna.


📜 SIMILAR VOLUMES


Determination of amphetamines in human u
✍ Francesca Bugamelli; Roberto Mandrioli; Annalisa Cavallini; Cesare Baccini; Matt 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 418 KB 👁 1 views

## Abstract A precise and feasible HPLC method has been developed for the analysis of amphetamine (AMPH), methamphetamine (MAMPH) and methylenedioxymethamphetamine (MDMA, ecstasy) in human urine. A chromatographic run on a C8 Genesis (150 mm×4.6 mm, 5 μm) column maintained at 30°C lasts about 17 mi

Sensitive determination of ethacrynic ac
✍ Pilar Campíns-Falcó; Rosa Herráez-Hernández; Adela Sevillano-Cabeza 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 367 KB