More than 1000 laboratories worldwide use phosphorimager systems for radioisotopic gel and blot quantification. This method is extraordinary sensitive and has a wide dynamic range, and it is therefore often preferred to conventional filmโ€based analysis. We checked the accuracy of our storage phosphor screen by exposing the same ^32^Pโ€labelled blot in different positions on the same screen. The first exposure took place at the top of the screen, an area used more often; the second exposure at a relatively littleโ€used area of the screen. As the screens are said to last indefinitely, regardless of how often they are used, we did not expect a difference in the results. In fact, we found a significant impact of the position of the gel on the results. The position that was used more often gave inaccurate results; in contrast, the unused area of the screen gave data that were confirmed by Xโ€ray film autoradiography. We conclude that, contrary to described properties, a deterioration of the phosphor screens takes place with repeated use. To avoid obtaining invalid data, we recommend frequent checks of the screens. Copyright ยฉ 2002 John Wiley & Sons, Ltd.


๐Ÿ“œ SIMILAR VOLUMES


Predictors of deterioration among patien
โœ Rudolf H. Moos; Bernice S. Moos; John W. Finney ๐Ÿ“‚ Article ๐Ÿ“… 2001 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 102 KB ๐Ÿ‘ 1 views

## Abstract The purpose of this study was to identify patients with substanceโ€use disorders who deteriorate during treatment, and to examine baseline predictors of deterioration. Three groups of 872 patients each, matched on number of problems at baseline, were selected from a larger sample based o

Deterioration of the nitrogen BET surfac
โœ Robert L. Rarick; Jeffrey J. Thomas; Bruce J. Christensen; Hamlin M. Jennings ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 346 KB

Gas sorption surface area measurements have been important for developing microstructural models for the structure of calciumsilicate-hydrate (C-S-H), the major hydration product of portland cement. However, surface area measurements using the nitrogen BET method have historically had high variabili

Comparison of photon-counting to storage
โœ Bjรถrn Cederstrรถm; Ursula Streubรผhr ๐Ÿ“‚ Article ๐Ÿ“… 2007 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 167 KB

Two digital mammography systems, one based on scanning photon counting silicon detectors and the other on storage phosphor plates (CR), have been compared in terms of image quality and dose. Sets of images of a contrast-detail phantom (CDMAM3.4) were acquired for each system and dose level. The imag